Mode Name
Description
Meter charge
Meter-charge
mode
Debug Serial
Service
Prints summary sheet.
Report
SP Mode Print
NIB Summary
Operation
Total engine
time
rotation cycle
Total counter
Controller total
counter display
Disp ROM
ROM version
ver
display
PM Counter
PM counter
display
PM Counter
Resets the PM
reset
counter
Diag result
Diagnostic
result display
Assert Info
SM
Enable or disable meter-charge mode.
Important: Turn the main switch off/on after changing
this setting.
Yes: Enabled
No: Disabled
Meter charge mode enabled:
• "Replace Maintenance Kit" is not displayed on the
operation panel when the PM counter runs out (the
technician replaces the maintenance kit items)
• The meter charge counter is shown immediately after
the Menu key is pressed.
• The technician must reset the PM counter after
replacing the fusing unit.
Meter charge mode disabled:
• "Replace Maintenance Kit" is displayed on the
operation panel when the PM counter runs out (the
user replaces the maintenance kit items)
• The meter charge counter is not shown when the
Menu key is pressed.
• The PM counter resets automatically after the user
replaces the fusing unit.
---
DFU
Prints the engine summary sheet.
Prints the NIB summary sheet.
Displays the total number of engine rotation cycles made
so far.
Note: One cycle is calculated as 3.7 s of drum rotation.
However, this counter also includes idle rotations.
This counter is not reset at PM.
Displays the controller total counter. This counter is used
for meter charge, and it appears when the user presses
the Menu key (if meter charge mode is enabled).
It does not count up when certain items, such as service
reports, are printed (see section 6.6.1. for a complete list
of conditions).
Displays the firmware version (system, engine, and
duplex).
Displays the PM counter. This is not a page counter. It
estimates the page count using the engine rotation cycle
count. It counts up one page when the engine has made
the average number of rotations that is required for one
page of a three-page job.
Resets the PM counter.
Important: If a technician replaces the PM items, reset
this counter after replacing these items.
Displays the controller self-diagnostic result.
---