Error Code ED
Unable to Init. ED

Touch panel initialization failed

User Check
- Check that nothing is placed on the touch panel.
Step
1
Touch panel harness connection
failure
2
Touch panel defective
3
Main PCB defective
Error Code F0
Unable to Init. F0

Flash file system error.

Step
1
Program malfunctioning
2
Main PCB defective
Error Code FE
Unable to Init. FE

ROM data acquisition error.

Step
1
Program malfunctioning
2
Main PCB defective
Cause
Check the connection and reconnect the harness.
Replace the LCD unit.
Replace the main PCB ASSY.
Cause
Reload firmware.
Refer to
Replace the main PCB ASSY.
Cause
Reload firmware.
Refer to
Replace the main PCB ASSY.