SC Tables: SC6xx
Mechanical counter error: BK
This SC is only for NA models.
The machine detects the mechanical counter error when SP5987-001 is set
610
D
to "1".
Disconnected mechanical counter
Defective mechanical counter
620
D
ADF communication error
Communication error between machine and ADF
Communication error between machine and ADF with ASAP is detected.
-01
-
Disconnected cable
ARDF defective
IPU board defective
External noise
Communication error between IPU and ADF
After the ARDF is detected, the break signal occurs or communication
timeout occurs.
-02
-
Incorrect installation of ARDF
ARDF defective
IPU board defective
External noise
Communication timeout error between IOB and finisher or mailbox
A break (low) signal is received from the finisher or the mailbox.
621
D
Disconnected cable
Defective IOB
Defective main board in the peripherals
SM
6-21
Service Call Conditions