Rev. 12/27/2012
Magnification
Use the S5S test chart to perform the following adjustment.
Sub Scan Magnification
1.
Place the test chart on the exposure glass and make a copy from one of the feed stations.
2.
Check the magnification ratio. Use SP4-008 (Scanner Sub Scan Magnification) to adjust if
necessary. Specification: ±0.9%.