Nortel business policy switch 2000 User Manual page 194

Table of Contents

Advertisement

194 Chapter 3 Using the console interface
Table 21 EAPOL security configuration screen options (continued)
Option
Administrative Traffic
Control
Operational Traffic
Control
Re-authenticate Now
Re-authentication
Re-authentication Period
Quiet Period
Transmit Period
Supplicant Timeout
208700-C
Description
Allows you to choose whether EAPOL authentication is set for incoming and
outgoing traffic or for incoming traffic only. For example, if you set the
specified unit/port field value to Incoming and Outgoing, and the EAPOL
authentication fails, then both incoming and outgoing traffic on the specified
unit/port is blocked.
Default
Incoming and Outgoing
Range
Incoming and Outgoing,Incoming Only
A read-only field that indicates the current administrative traffic control
configuration for the specified unit/port (see preceding field description). This
read-only field does not appear when the Unit/Port field value is set to All.
Default
Incoming and Outgoing
Range
Incoming and Outgoing,Incoming Only
Allows you to activate EAPOL authentication for the specified unit/port
immediately, without waiting for the Re-Authentication Period to expire.
Default
No
Range
No,Yes
Allows you to repeat EAPOL authentication for the specified unit/port
according to the time interval value configured in the Re-Authentication
Period field (see next field description).
Default
Enabled
Range
Enabled,Disabled
When the Re-Authentication field value (see preceding field) is set to
enabled, this field allows you to specify the time period between successive
EAPOL authentications for the specified unit/port.
Default
3600 seconds
Range
1 to 604800 seconds
Allows you to specify the time period between any single EAPOL
authentication failure and the start of a new EAPOL authentication attempt.
Default
60 seconds
Range
0 to 65535 seconds
Allows you to specify how long the switch waits for the supplicant to respond
to EAP Request/Identity packets.
Default
30 seconds
Range
1 to 65535 seconds
Allows you to specify how long the switch waits for the supplicant to respond
to all EAP packets, except EAP Request/Identity packets.