RIGID PIPE VENTING SYSTEMS

BASIC HORIZONTAL & VERTICAL TERMINATIONS
Rigid Pipe Vent Systems offer a complete line of
component parts for installation of both horizontal
and vertical installations. Many items are offered
in decorative black, as well as galvanized finish.
The minimum components required for a basic
Horizontal Termination are:
1
AstroCap XL Termination Cap
1
90
Elbow
o
1
Rigid Pipe Adaptor
1
Wall Thimble
1
Length of rigid pipe to suit wall thickness
The minimum components required for a basic
Vertical Termination are:
1
Vertical Termination Cap
1
Rigid Pipe Adaptor
1
Lengths of pipe to adequately
penetrate roof
1
Ceiling Firestop
1
Flashing
1
Storm Collar
Wall thickness
is measured from the back
standoffs to the inside mounting surface of
termination cap. For siding other than vinyl, furring
strips may be used, instead of a vinyl siding
standoff, to create a level surface to mount the
vent terminal. The Terminal must not be recessed
into siding. Measure the wall thickness including
furring strips.
If a Vinyl Siding Standoff is required (it must be
used with vinyl siding), measure to outside surface
of wall without siding and add 2 inches.
WARNING:
Do not combine venting components from
different venting systems.
Exception: However, use of the the AstroCap
XL
is acceptable with all systems.
TM
This product has been evaluated by Intertek for
using a Rigid Pipe Adaptor in conjunction with
Simpson DV Pro, Metal-Fab Sure-Seal, ICC
Excel and Selkirk Direct-Temp systems. Use
of these systems with the Rigid Pipe adaptor
is deemed acceptable and does not affect the
Warnock Hersey/Intertek listing of components.
The FPI AstroCap XL
is certified for installations using FPI venting systems as well as Simpson Dura-Vent
TM
Direct-Temp. AstroCap XL
is a proprietary trademark of FPI Fireplace Products International Ltd. Dura-Vent® and Direct Vent are registered and/or
TM
proprietary trademarks of Simpson Dura-Vent Co. Inc.
Vertical Terminal
Storm Collar
Flashing
Ceiling Firestop
Pipe Length
Pipe
Length
Alternate Horizontal
Termination Caps
Alternate Snorkel
Termination Cap
installation
Vinyl Siding
Standoff (Optional)
Wall Thimble
(Mandatory in all
Horizontal Terminations)
Pipe Length
90 Elbow
o
Rigid Pipe
Adaptor (770-994)
When using Rigid Vent other than
Simpson Dura-Vent, 3 screws must be
used to secure rigid pipe to adaptor.
Direct Vent Pro, ICC Excel and Selkirk
®
Regency Horizon
®
HZ54E-10 Gas Fireplace
|
21
Vent Guard - if required*
(Part #946-506/P)
AstroCap XL
Termination Cap
(Part #946-623/P)
|
21

Advertisement

Table of Contents
loading

This manual is also suitable for:

Horizon hz54e-lp10

Table of Contents