Mantel Clearances; Mantel Leg Clearances - Regency Horizon HZ54E-NG10 Owners & Installation Manual

Hide thumbs Also See for Horizon HZ54E-NG10:
Table of Contents

Advertisement

installation
|
12

MANTEL CLEARANCES

Due to the extreme heat this fireplace emits, the mantel clearances are critical. Combustible mantel clearances from top of front facing are shown in
the diagram on the right.
Note: A non-combustible mantel may be
installed at a lower height if the framing
is made of metal studs covered with a
non-combustible board.
Note: Ensure the paint that is used on the mantel
and the facing is "High Quality" or the paint
may discolour.

MANTEL LEG CLEARANCES

Combustible mantel leg clearances as per diagram:
12 |
®
Regency Horizon
HZ54E-10 Gas Fireplace
10
14
12
30
20
30
10
0
To Unit
Base Legs
MANTEL LEG
Allowable mantel
leg projection
8
6
4
2
13" (330mm)
3 ½" (89mm)
Drywall
1" (25mm)
Metal Stud
(On Edge)
21
Standoff
20
Top of
Fireplace
28-1/8
Opening
4 (102mm)
Non-Combustible
1.5" (38mm)
5-1/2 (140mm)
8 (203mm)
11 (279mm)
Combustible Material
Non-combustible facing.
Must be supported
using steel stud or
the framing kit

Advertisement

Table of Contents
loading

This manual is also suitable for:

Horizon hz54e-lp10