Regency Horizon HZ54E-NG11 Owners & Installation Manual

Gas fireplace
Table of Contents

Advertisement

Quick Links

Regency Horizon ® HZ54E
www.regency-fire.com
WARNING
FIRE OR EXPLOSION HAZARD
failure to follow safety warnings exactly could result in serious
injury, death, or property damage.
- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
- WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch: do not use any phone in your building.
Leave the building immediately.
• Immediately call your gas supplier from a neighbour's phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas supplier, call the fire department.
- Installation and service must be performed by a qualified installer, service agency or the gas supplier.
Tested by:
Certified to/Certifié pour: CSA 2.17-2017
920-004b
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
Gas Fireplace
ANSI Z21.88-2017
CSA 2.33-2017
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
Owners &
Installation Manual
MODELS: HZ54E-NG11 Natural Gas
HZ54E-LP11 Propane
Horizon HZ54E Product Video
03.28.19

Advertisement

Table of Contents
loading

Summary of Contents for Regency Horizon HZ54E-NG11

  • Page 1 Owners & Regency Horizon ® HZ54E Installation Manual Gas Fireplace MODELS: HZ54E-NG11 Natural Gas HZ54E-LP11 Propane www.regency-fire.com Horizon HZ54E Product Video WARNING FIRE OR EXPLOSION HAZARD failure to follow safety warnings exactly could result in serious injury, death, or property damage.
  • Page 2: On Demand Pilot Light (Seven Day Safety Timer)

    Warnock Hersey/Intertek for both safety and efficiency. As it also bears our own mark, it promises to provide you with economy, comfort and security for many trouble free years to follow. Please take a moment now to acquaint yourself with these instructions and the many features of your Regency Fireplace.
  • Page 3 Title 24 CFR, Part 3280, in the Untied States, or the Standard for Installation in Mobile Homes, CAN/CSA Z240 MH, in Canada. R e g e n c y H o r i z o n Horizon HZ54 Product Video Gas Inserts Benefits Video Regency Horizon ® HZ54E-11 Gas Fireplace...
  • Page 4: Table Of Contents

    Terminations for HZ54E-LP .........30 Venting Arrangements ..........33 Allowable Vertical Terminations for HZ54E-NG ..33 ALL PICTURES / DIAGRAMS SHOWN THROUGHOUT THIS MANUAL ARE FOR ILLUSTRATION PURPOSES ONLY. ACTUAL PRODUCT MAY VARY DUE TO PRODUCT ENHANCEMENTS. Regency Horizon ® HZ54E-11 Gas Fireplace...
  • Page 5: Copy Of Safety Decal

    Faceplate and Glass door have the gas appliance is installed. been removed the rating plate will be attached to a chain. DO NOT REMOVE DECAL FROM UNIT. Regency Horizon ® HZ54E-11 Gas Fireplace...
  • Page 6: Ma Code - Co Detector

    (e) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipm ent, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation. Regency Horizon ® HZ54E-11 Gas Fireplace...
  • Page 7: Unit Dimensions

    Unit Dimensions Faceplate & Door frame overlay Dimensions Verona Glass Surround (Not Shown) Dimensions: 58-9/16" W x 27-1/8" H Regency Horizon ® HZ54E-11 Gas Fireplace...
  • Page 8: Important Message

    National Electrical Code, ANSI/NFPA 70 or CSA C22.1 Canadian Electrical Code. 3) See general construction and assembly in- structions. The appliance and vent should be enclosed. Regency Horizon ® HZ54E-11 Gas Fireplace...
  • Page 9: Lighting Procedure

    2. Press and release the ON/OFF button on the remote handheld transmit- ter (see Diagram 2). An audible beep should be heard from the receiver. ON/OFF Button Diagram 2 Remote shown in Manual Mode on Hi Regency Horizon ® HZ54E-11 Gas Fireplace...
  • Page 10: Copy Of Lighting Plate Instructions

    If service is to be performed–you must disconnect power and shut off gas to the unit. Utiliser l'interrupteur mural ou la télécommande pour mettre le système sur ''OFF''. Lors de l'entretien de l'appareil –débrancher l'alimentation électrique et couper le gaz de l'appareil. DO NOT REMOVE THIS INSTRUCTION PLATE 919-401a Regency Horizon ® HZ54E-11 Gas Fireplace...
  • Page 11: Proflame I Remote Control Operating Instructions

    The receiver instruction may not be indepen- dent when part of the IFC. Figure 2: Transmitter LCD Display Fig3: Battery Figure 3: Battery Compartment (Proflame II handheld shown) compartment. Regency Horizon ® HZ54E-11 Gas Fireplace 12.17.18 920-019...
  • Page 12 Transmitter LCD display will only show the room temperature (Fig. 6). At the same time the Receiver will turn off the appliance. A single “beep” from the Receiver confirms reception of the command. Figure 9 Figure 10 Regency Horizon ® HZ54E-11 Gas Fireplace...
  • Page 13 To de-activate this function, press the MODE and UP Keys at the same Keys (fig.1) to turn on, off or adjust the fan speed (fig. 14). A single “beep” time. will confirm reception of the command. Figure 18 Figure 13 Figure 14 Regency Horizon ® HZ54E-11 Gas Fireplace 12.17.18 920-019...
  • Page 14 5. Use the up or down arrow button to program out the function on the remote. Note: You should never program out the fan (If installed) feature on the remote. It is not possible to remove the thermostat mode on this remote control. Regency Horizon ® HZ54E-11 Gas Fireplace 920-019 01.16.19...
  • Page 15: Installer's Information

    The Heat Release Kit expels warm air from the fireplace to the outside of the building, allowing the fireplace to be operated with less heat entering the room. The kit may be used on either the left or right side. Regency Horizon ® HZ54E-11 Gas Fireplace...
  • Page 16: Clearances

    - when 1-1/2" firestop is used. Installed Close Installed Close to Ceiling to Floor Non-Combustible Requirements Metal Stud (header) 60-1/2" (1537mm) Wood Stud Wood Stud Non-combustible Material 52-7/8” Non-combustible Material 3-7/8" 5-1/2” ( 99mm) (140mm) Regency Horizon ® HZ54E-11 Gas Fireplace...
  • Page 17: Non Combustible Facing Board

    While every precaution is taken in providing the recommendations on preparation and finish, given the variations in paint quality, with temperature limits and workmanship in application, Regency is unable to guarantee the life of the joint compounds, paint or any other finish materials or workmanship applied to or used in any application surrounding the fireplace.
  • Page 18: Mantel Clearances

    Top of Fireplace 28-1/8” Opening To Unit Base Legs Mantel Leg Clearances Combustible mantel leg clearances as per diagram: 4”(102mm) MANTEL LEG Non-Combustible 1.5" (38mm) 5-1/2” (140mm) Allowable mantel leg projection 8” (203mm) 11” (279mm) Regency Horizon ® HZ54E-11 Gas Fireplace...
  • Page 19: Framing & Finishing

    52-7/8 ” Unit shown without faceplate for Illustrative purposes only NOTE: The Verona Glass Surround (not shown) opening needs to be 60- 1/16" W x 28 5/8" H Regency Horizon ® HZ54E-11 Gas Fireplace...
  • Page 20: Unit Assembly Prior To Installation

    Standoff or gas burning appliance. Each direct vent gas appliance must use it's own Remove screws to Diagram 2 separate vent system. Common vent systems are prohibited. release standoffs Regency Horizon ® HZ54E-11 Gas Fireplace...
  • Page 21: Framing Dimensions

    & wall finishes. Important: The minimum framing dimensions given for height, width and depth must be maintained even if using non combustible materials. Dangerous operating conditions will occur if minimum framing dimensions are not adhered to. Regency Horizon ® HZ54E-11 Gas Fireplace...
  • Page 22 4. Attach both vertical studs (478-015) and secure using 6 screws (2 at bottom, 2 at top and 2 on the sides) as shown NOTE: Ensure the flat side of the steel stud is facing the wood framing. Regency Horizon ® HZ54E-11 Gas Fireplace 09.15.14 919-441...
  • Page 23: Wall Mount On / Off Switch / Receiver Installation

    11. Using the two (2) screws provided secure the cover plate to the Receiver. Low Voltage Junction Box Profl ame Receiver J-Box Receiver Slider Switch Wall Plate 10 ft. wire harness with 12 pin connector Diagram 1 Regency Horizon ® HZ54E-11 Gas Fireplace...
  • Page 24: Vent Restrictor Position

    THIS HOLE SETS THE VENTR ESTRICTOR VENT RESTRICTOR AT 2-1/2” AT 1” Vent Restrictor Set 5 Vent Restrictor Set 3 2” SET 4 THIS HOLE SETS THE VENTR ESTRICTOR AT 2” Vent Restrictor Set 4 Regency Horizon ® HZ54E-11 Gas Fireplace...
  • Page 25: Exterior Vent Termination Requirements

    * Clearance in accordance with local installation codes and the requirements of the gas supplier 3 feet (91cm) within a height of 15 feet (4.5m) above the meter / regulator assembly 3 feet (91cm) above - if within 10 feet (3m) horizontally Regency Horizon ® HZ54E-11 Gas Fireplace...
  • Page 26: Venting Arrangements

    2) Only Flex pipe purchased from FPI may be used for Flex installations. 3) Horizontal vent must be supported every 3 feet. 4) A wall thimble is mandatory for all horizontal terminations due to high temperatures. Regency Horizon ® HZ54E-11 Gas Fireplace...
  • Page 27: Rigid Pipe Venting Systems

    Direct Vent Pro, ICC Excel and Selkirk Direct- ® Temp. AstroCap XL is a proprietary trademark of FPI Fireplace Products International Ltd. Dura-Vent® and Direct Vent are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc. Regency Horizon ® HZ54E-11 Gas Fireplace...
  • Page 28: 5" X 8" Rigid Pipe Cross Reference Chart

    5” X 8” RIGID PIPE CROSS REFERENCE CHART Components from different Manufacturers may not be mixed. Not all rigid pipe components are available directly from Regency. Note: The listed manufacturers may have other lengths not shown on this chart, which would also be approved.
  • Page 29 1 foot of run towards the termination. 36” (914mm) 29-13/16” (757mm) 39-7/16” (1002mm) Never allow the vent to run downward - this could cause high temperatures and may present a possible fi re hazard. 48” (1219mm) 38-1/4” (972mm) 47-7/8” (1216mm) Regency Horizon ® HZ54E-11 Gas Fireplace...
  • Page 30: Venting Arrangements

    • A wall thimble is mandatory for all horizontal terminations due to • A wall thimble is mandatory for all horizontal terminations due high temperatures. to high temperatures. Regency Horizon ® HZ54E-11 Gas Fireplace...
  • Page 31 5' Min. 4' Max. 10' Min. 7' Max. between 90 elbows is 6' Min. 6' Max. 11' Min. 9' Max. required. VENT RESTRICTOR SETTING: Vent restrictor factory set at Set 1, no adjustment required. Regency Horizon ® HZ54E-11 Gas Fireplace...
  • Page 32 Please note min. 1 foot 5' Min. 6' Max. 8' Min. between 90 elbows is 6' Min. 8' Max. 9' Min. required. VENT RESTRICTOR SETTING: Vent restrictor factory set at Set 1, no adjustment required. Regency Horizon ® HZ54E-11 Gas Fireplace...
  • Page 33: Venting Arrangements

    Set 1 to Set 2 or Set 4 if required. Note: Must use optional flue adaptor when using Rigid Pipe (Part # 770-994). Max. 10’ (3m)(centerline to centerline) Minimum length of pipe between elbows 12” (305mm) Regency Horizon ® HZ54E-11 Gas Fireplace...
  • Page 34: Venting Arrangements

    Set 1 to Set 4 or Set 5 if required. Note: Must use optional flue adaptor when using Rigid Pipe (Part # 770-994). Max. 10’ (3m)(centerline to centerline) Minimum length of pipe between elbows 12” (305mm) Regency Horizon ® HZ54E-11 Gas Fireplace...
  • Page 35: Unit Installation With Horizontal Termination

    “Mill-Pac” sealant (supplied) to every inner pipe connection. Failure to do so Diagram 4 may result in drafting or performance issues not covered under warranty. Regency Horizon ® HZ54E-11 Gas Fireplace...
  • Page 36: Unit Installation With Vertical Termination

    Diagram 5 or local codes. Note that for steep roof pitches, the vertical height must be increased. Diagram 3 Regency Horizon ® HZ54E-11 Gas Fireplace...
  • Page 37: Unit Installation

    1-3/8"(35mm) and fasten with the 3 screws. NOTE: Horizontal sections must be sup- Fourrures en bois ported at intervals not exceeding 3 feet (0.9 meter). (Flame picture and performance will be affected by sags in the liner). Regency Horizon ® HZ54E-11 Gas Fireplace...
  • Page 38: High Elevation

    Do not use open flame for leak testing. Note: To properly check gas pressure, both inlet and manifold pressures should be checked using the valve pressure ports on the valve. Regency Horizon ® HZ54E-11 Gas Fireplace...
  • Page 39: Valve Cover Removal

    2) The valve cover is located on the right side underneath the glass door - loosen 2 screws securing the valve cover (see Diagram 1 below). Diagram 3 Diagram 1 Valve cover 3) Slide the valve cover upward. Diagram 2 Regency Horizon ® HZ54E-11 Gas Fireplace...
  • Page 40: Aeration Adjustment

    NG with Logs Full open the aeration controls is NOT NG with Stones Full open covered under warranty. 1/2" LP with Logs Full open LP with Stones Full open Venturi Cap Regency Horizon ® HZ54E-11 Gas Fireplace...
  • Page 41: Wiring Diagram

    Caution: Ensure that the wires do not touch any hot surfaces and are away from sharp edges. CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Regency Horizon ® HZ54E-11 Gas Fireplace...
  • Page 42: Optional Wall Thermostat Installation

    - see picture below. NOTE: When the remote receiver is set to ON position, the remote control transmitter and all of its features are now dis- abled. CAUTION Do not wire Thermostat wires to 120V wire. Regency Horizon ® HZ54E-11 Gas Fireplace...
  • Page 43: Optional Reflective Panel Installation

    Bracket Fit side panel tab into slot Right side back panel tab fi tted into slot Left side panel in position Bracket shown in place on right side of the fi rebox Regency Horizon ® HZ54E-11 Gas Fireplace 10/08/09 918-754a...
  • Page 44: Glass Crystals Or Optional Stones

    Pebbles HZ54E 6 lbs 9lbs 2 packages (6 x bags pebbles) Natural River Pebbles shown surrounding the Horizon Burner Glass Crystals shown surrounding the Burner Optional Volcanic Stones + Glass Crystals shown on burner. Regency Horizon ® HZ54E-11 Gas Fireplace...
  • Page 45: Optional Driftwood Log Set Installation

    Secure template in place with magnets (supplied) on each side. These cut lines for HZ40E only HZ54E - existing Pilot HZ54E - new Pilot Hood Top View - showing both HZ54E/HZ40E cut Hood template out along dotted line Regency Horizon ® HZ54E-11 Gas Fireplace 02.10.16 919-258a...
  • Page 46 HZ54E shown - Completed Install 14. Carefully remove magnets and log placement template, slightly lifting logs as required. Match pin and pin landing Logs 1 and 3. HZ40E shown - Completed Install Regency Horizon ® HZ54E-11 Gas Fireplace 919-258a 02.10.16...
  • Page 47: Faceplate & Door Frame Overlay Installation

    Mesh screen from inner door frame (1) to be removed and installed into outer door frame (3) as shown. Bend the six tabs down to secure the mesh to the outer door frame. Tabs 12.15.14 919-387 Regency Horizon ® HZ54E-11 Gas Fireplace...
  • Page 48 There is a top and bottom, the top of the faceplate has a full 1" return whereas the bottom only has a 1/2" return as shown in the diagram below. Regency Horizon ® HZ54E-11 Gas Fireplace 919-387 12.15.14...
  • Page 49 Also if necessary, the faceplate may be adjusted up and down by loosening the top screw as shown in the diagram below and sliding the plate up or down as required. Faceplate Mounting Slots Completed Faceplate Installation Regency Horizon ® HZ54E-11 Gas Fireplace 919-387 12.15.14...
  • Page 50: Fan Installation

    Aerial View of the inside of the unit shown. 7) Remove bottom cover by undoing 3 screws securing it to the firebox base, lift up and out. Aerial View of the inside of the unit shown. Regency Horizon ® HZ54E-11 Gas Fireplace...
  • Page 51 12) Remove 8 screws to remove the fan access panel cover - located on Ground Lug the left hand side floor of the firebox. 16) Slide the thermodisc into the bracket on the bottom side of the fan access panel - check fan access panel gasket - replace if necessary. Fan Access Panel Regency Horizon ® HZ54E-11 Gas Fireplace...
  • Page 52 IMPORTANT: These fans collect a lot of dust from within your home. Ensure you maintain these fan motors on a regular basis by vacuuming the fan blades and housing using a soft brush nozzle. Regency Horizon ® HZ54E-11 Gas Fireplace...
  • Page 53: Wiring Diagram With Optional Fan

    Caution: Ensure that the wires do not touch any hot surfaces and are away from sharp edges. CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Regency Horizon ® HZ54E-11 Gas Fireplace...
  • Page 54: Operating Instructions

    Use a non-abrasive cleaner and DO NOT ATTEMPT TO CLEAN THE GLASS WHILE IT IS HOT. Regency Horizon ® HZ54E-11 Gas Fireplace...
  • Page 55: Lighting Procedure

    1. Turn the wall mounted switch or remote to the "OFF" position. 2. Press "OFF" on the remote control. ON/OFF Button 3. Turn the gas control knob to the "OFF" position to turn off the pilot. Diagram 2 Remote shown in Manual Mode on Hi Regency Horizon ® HZ54E-11 Gas Fireplace...
  • Page 56: Copy Of Lighting Plate Instructions

    If service is to be performed–you must disconnect power and shut off gas to the unit. Utiliser l'interrupteur mural ou la télécommande pour mettre le système sur ''OFF''. Lors de l'entretien de l'appareil –débrancher l'alimentation électrique et couper le gaz de l'appareil. DO NOT REMOVE THIS INSTRUCTION PLATE 919-401a Regency Horizon ® HZ54E-11 Gas Fireplace...
  • Page 57: Maintenance Instructions

    Replacement of the glass panels resealed & reinstalled in accordance with the should be done by a licensed or manufacturer's instructions. qualified service person. 8) Verify operation after servicing. General Vent Regency Horizon ® HZ54E-11 Gas Fireplace...
  • Page 58: Glass Door Removal

    4) Remove the door frame overlay by swinging out 45 from the bottom and lift up and out. 6) Remove valve cover - (see valve cover removal section in this manual). Regency Horizon ® HZ54E-11 Gas Fireplace...
  • Page 59: Safety Screen Removal / Installation

    7. Secure the assembly with screws on each side as shown below. 3. Install screen into inner door trim (3). Secure screen by bending down the 6 tabs as shown Tabs Regency Horizon™ HZ40E-10 Gas Fireplace Regency Horizon ® HZ54E-11 Gas Fireplace...
  • Page 60: Valve Tray Replacement

    Prior to removing burner - remove the following (if installed): 4) Remove the door frame overlay by swinging out 45 from the bottom -crystals and lift up and out. -pebbles -spa stones -logs -Inner panels Regency Horizon ® HZ54E-11 Gas Fireplace...
  • Page 61: Hz54E-Ng Unit

    8) Partially lift out valve tray. 9) Disconnect the inlet gas line. Green Wire Orange Wire 4) Disconnect the green ground wire from the valve bracket. 10) Replace valve and reverse steps. Green ground wire Regency Horizon ® HZ54E-11 Gas Fireplace...
  • Page 62: Hz54E-Lp Unit

    Location of screws securing burner 9) Partially lift out valve tray. 10) Disconnect the inlet gas line. Burner Bracket 5) With burner removed - lift out burner tray. Gas Inlet Line 11) Replace valve and reverse steps. Regency Horizon ® HZ54E-11 Gas Fireplace...
  • Page 63: Main Assembly

    Valve wiring w/ IPI/CPI switch 911-010 Stepper Motor/Modulator - NG 911-011 Stepper Motor/Modulator - LP 910-576 Wall Switch/Receiver cover (white) 920-004 Manual 911-265 Ignition Board 946-721 AC Adaptor 910-592 GTMF Hand held transmitter 911-030 Fan Control Module Regency Horizon ® HZ54E-11 Gas Fireplace...
  • Page 64 Regency Horizon ® HZ54E-11 Gas Fireplace...
  • Page 65: Warranty

    946-676 Copper Crystals 946-742 Caramel Luster Firebeads 946-677 Starfire Crystals 1 pound bag of glass crystals Part # Description 946-735 Black Firebeads 946-736 Sangria Luster Firebeads 946-737 Glacier Ice Firebeads 946-738 Caramel Luster Firebeads Regency Horizon ® HZ54E-11 Gas Fireplace...
  • Page 66 FPI is not responsible for results or costs of workmanship of unauthorized FPI dealers or agents in the negligence of their service work. Revision Date: February 2019 Regency Gas Products Warranty Regency Horizon ® HZ54E-11 Gas Fireplace...
  • Page 67 Freight damages for products or parts are not covered under the terms of the warranty. Products made or provided by other manufacturers and used in conjunction with the FPI appliance without prior authorization from FPI may void this warranty. Revision Date: February 2019 Regency Gas Products Warranty Regency Horizon ® HZ54E-11 Gas Fireplace...
  • Page 68 Product Registration and Customer Support: Thank you for choosing a Regency Fireplace. Regency strives to be a world leader in the design, manufacture, and marketing of hearth products. To provide the best support for your product, we request that you complete a product registration form at http://www.regency-fire.com/Customer-Care/Warranty-Registration.aspx...
  • Page 69 Product Registration and Customer Support: Thank you for choosing a Regency Fireplace. Regency strives to be a world leader in the design, manufacture, and marketing of hearth products. To provide the best support for your product, we request that you complete a product registration form found on our Web Site under Customer Care within ninety (90) days of purchase.
  • Page 70 Regency Horizon ® HZ54E-11 Gas Fireplace...
  • Page 72 Installer: ___________________________________________________________ Phone #: ___________________________________________________________ Date Installed: ______________________________________________________ Serial No.: __________________________________________________________ Horizon HZ54 Video Printed in Canada Regency Horizon and SureFire™ are trademarks of FPI Fireplace Products International Ltd. © Copyright 2019, FPI Fireplace Products International Ltd. All rights reserved.

This manual is also suitable for:

Horizon hz54eHorizon hz54e-lp11

Table of Contents