installation
|
14
UNIT ASSEMBLY PRIOR TO
INSTALLATION
The Top Standoff/ Nailing Strip, side nailing strips and standoffs must be
correctly positioned and attached to the unit before sliding the unit into position.
STANDOFF ASSEMBLY
The top, side and rear standoffs are shipped in a flat position and must be
folded into shape and attached - see diagram 1.
1) Remove the standoffs from the unit.
2) Take each standoff and bend into the correct shape. Bend up at the bend
lines until the screw holes in the standoff and the pre-punched screw holes
on the unit line up.
Standoff
Remove screws to
release standoffs
14 |
®
Regency Horizon
HZ54E-10 Gas Fireplace
Diagram 1
Standoff
Diagram 2
NAILING STRIPS
The nailing strips come attached to the unit. There is 1 plate on each side,
that can be folded out as required. The side nailing strips are secured to the
framing.
Standoff
Nailing Strips
Nailing Strips
IMPORTANT NOTE
Framing depth measurement is noted with the
side nailing strips set as far forward on the
firebox as possible. The nailing strips can be
adjusted back up to 3-1/8" to allow for varying
thicknesses in non-combustible material & wall
finishes.
VENTING INTRODUCTION
The HZ54E uses the "balanced flue" technology Co Axial system. The
inner liner vents products of combustion to the outside while the outer liner
draws outside combustion air into the combustion chamber thereby eliminating
the need to use heated room air for combustion and losing warm room air
up the chimney.
Note: These flue pipes must not be connected to any other appliance.
The gas appliance and vent system must be vented directly to the outside of
the building, and never be attached to a chimney serving a separate solid fuel
or gas burning appliance. Each direct vent gas appliance must use it's own
separate vent system. Common vent systems are prohibited.
Diagram 3
Shipping brackets -
remove after shipped.
Standoff