Rigid Pipe Venting Systems - Regency Panorama P36E-NG11 Owners & Installation Manual

Zero clearance direct vent gas fireplace
Table of Contents

Advertisement

RIGID PIPE VENTING SYSTEMS

Horizontal or Vertical Terminations
The minimum components required for a basic horizontal termination are:
1
Horizontal Termination Cap
1
90
o
Elbow
1
Rigid Pipe Adaptor
1
Wall Thimble
1
Length of pipe to suit wall thickness (see chart)
Wall thickness is measured from the back standoffs to the inside mounting
surface of termination cap. For siding other than vinyl furring strips may be
used, instead of the vinyl siding standoff, to create a level surface to mount the
vent terminal. The Terminal must not be recessed into siding. Measure the wall
thickness including furring strips.
If a Vinyl Siding Standoff is required (it must be used with vinyl siding), measure
to outside surface of wall without siding and add 2 inches.
Alternate
Horizontal
Termination
Caps
WARNING:
Do not combine venting components from
different venting systems.
However use of the the AstroCap
Regency Riser is acceptable with all systems.
This product has been evaluated by Intertek
when using a rigid pipe adaptor and use of
any of the specific chimney systems listed in
this manual. Use of these systems with the
rigid pipe adaptor is deemed acceptable and
does not affect the Intertek WHI listing of these
components.
The Regency AstroCap
TM
chimney systems listed in this manual. AstroCap
Termination
Storm Collar
Flashing
Ceiling Firestop
and
TM
and Regency Riser Vent terminal are certified for installations using Regency venting systems as well as any specific
is a proprietary trademark of Regency Fireplace Products.
TM
Vertical
Cap
Pipe Length
o
90 Elbow
24" Pipe
Length
Rigid Pipe Adaptor
(Must be used with all Rigid Piping)
Flat Wall Installation
Wall Thickness
Vent Length Required
(inches)
4" - 5-1/2"
7" - 8-1/2"
10" - 1-1/2"
9" - 14-1/2"
11" - 14-5/8" Adj. Pipe
15" - 23-1/2"
Corner Installation
Wall Thickness
Vent Length Required
(inches)
3-1/4" - 6-3/4"
11" - 14-5/8" Adj. Pipe
7-3/4" - 16-1/4"
17" - 24" Adj. Pipe
7-1/4" - 8-3/4"
4-1/4" - 5-3/4"
Vinyl Siding
Standoff (Optional)
Wall Thimble
Adj.Pipe Length
11" - 14-5/8"
When using Rigid Vent other than
Simpson Dura-Vent, 3 screws must be
used to secure rigid pipe to adaptor.
P36E-11 Zero Clearance Direct Vent Gas Fireplace
installation
(inches)
6"
9"
12"
17" - 24" Adj.
(inches)
6" + 12"
9" + 9"
6" + 9"
Horizontal
Termination
Cap
|
31