Rigid Pipe Venting Systems
Horizontal or Vertical Terminations
The minimum components required for a basic horizontal termination are:
1
Horizontal Termination Cap
1
90
Elbow
o
1
Rigid Pipe Adaptor
1
Wall Thimble
1
Length of pipe to suit wall thickness
(see chart)
Wall thickness is measured from the back standoffs
to the inside mounting surface of termination cap. For
siding other than vinyl furring strips may be used,
instead of the vinyl siding standoff, to create a level
surface to mount the vent terminal. The Terminal
must not be recessed into siding. Measure the wall
thickness including furring strips.
If a Vinyl Siding Standoff is required (it must be
used with vinyl siding), measure to outside surface
of wall without siding and add 2 inches.
Vertical
Termination
Cap
Storm Collar
Flashing
Ceiling Firestop
Pipe Length
90 Elbow
24" Pipe
Length
Rigid Pipe Adaptor
The FPI AstroCap
TM
and FPI Riser Vent terminal are certified for installations using FPI venting systems as well as Simpson Dura-Vent
can Metal Products, Olympia Ventis DV, Security Secure Vent
International Ltd. Dura-Vent® and Direct Vent are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc.
|
48
Grandview® G800EC Gas Fireplace
Vinyl Siding
Standoff (Optional)
Wall Thimble
Adj.Pipe Length
11" - 14-5/8"
o
®
Wall Thickness (inches)
4" - 5-1/2"
7" - 8-1/2"
10" - 11-1/2"
9" - 14-1/2"
15" - 23-1/2"
Wall Thickness (inches)
3-1/4" - 6-3/4"
7-3/4" - 16-1/4"
7-1/4" - 8-3/4"
4-1/4" - 5-3/4"
Horizontal
Termination
Cap
, AmeriVent Direct Vent. AstroCap
Flat Wall Installation
Vent Length Required (inches)
11" - 14-5/8" Adj. Pipe
17" - 24" Adj. Pipe
Corner Installation
Vent Length Required (inches)
11" - 14-5/8" Adj. Pipe
17" - 24" Adj. Pipe
6" + 12"
9" + 9"
6" + 9"
WARNING:
Do not combine venting components from
different venting systems.
However use of the AstroCap
is acceptable with all systems.
This product has been evaluated by Intertek
for using a Rigid Pipe Adaptor in conjunction
with DuraVent Direct Vent, Selkirk Direct-Temp,
Ameri Vent Direct venting, Olympia Ventis DV
and Security Secure Vent systems. Use of these
systems with the Rigid Pipe Adaptor is deemed
acceptable and does not affect the Intertek WHI
listing of components.
is the proprietary trademark of FPI Fireplace Products
TM
6"
9"
12"
Alternate
Horizontal
Termination
Caps
and FPI Riser