Venting Arrangements; Allowable Vertical Terminations For Hz54E-Lp - Regency Horizon HZ54E-NG10 Owners & Installation Manual

Hide thumbs Also See for Horizon HZ54E-NG10:
Table of Contents

Advertisement

installation
|
28

VENTING ARRANGEMENTS

ALLOWABLE VERTICAL TERMINATIONS FOR HZ54E-LP

The shaded area in the diagram shows all allowable
combinations of straight vertical and offset to vertical
terminations, using two 90
elbows, with Rigid Pipe Venting
o
Systems for Propane. Two 45
elbow. Maximum of four 45
o
Please note min. 1 foot between 90
elbows is required.
Vent must be supported at offsets.
Firestops are required at each floor level and
whenever passing through a wall.
Maintain clearances to combustibles as listed in
the "Clearances" section.
Refer to the "Vent Restrictor Position" section for
details on how to change the vent restrictor from
the factory setting of Set 1 to Set 4 or Set 5
if required.
Note: Must use optional flue adaptor when using
Rigid Pipe (Part # 770-994).
28 |
®
Regency Horizon
HZ54E-10 Gas Fireplace
elbows equal to one 90
o
o
elbows allowed.
o
2
4
0
40
38
36
34
32
30
Vent Restrictor on Set 5
28
26
24
22
Vent Restrictor on Set 4
20
18
16
14
12
10
8
6
4
2
0
Max. 10 (3m)(centerline to centerline)
Minimum length of pipe
between elbows 12 (305mm)
Horizontal (Feet)
8
6
10
12
Vent Restrictor on Set 1
(factory setting)
14
18
16