Regency Horizon HZ30E-NG10 Owners & Installation Manual

Hide thumbs Also See for Horizon HZ30E-NG10:
Table of Contents

Advertisement

Quick Links

Regency Horizon
Gas Fireplace
Horizon HZ30E Product Video
WARNING
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result in serious
injury, death, or property damage.
- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other
appliance.
- WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
• Do not touch any electrical switch: do not use any phone in your building.
Leave the building immediately.
• Immediately call your gas supplier from a neighbour's phone. Follow the gas supplier's
instructions.
• If you cannot reach you gas supplier, call the fire department.
- Installation and service must be performed by a qualified installer, service agency or the gas supplier.
Tested by:
919-362a
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
®
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
HZ30E
www.regency-fire.com
Owners &
Installation Manual
30E
MODELS:
HZ
-NG10 Natural Gas
30E
HZ
-LP10 Propane
09.15.15

Advertisement

Table of Contents
loading

Summary of Contents for Regency Horizon HZ30E-NG10

  • Page 1 Regency Horizon HZ30E ® Owners & Installation Manual Gas Fireplace MODELS: -NG10 Natural Gas -LP10 Propane Horizon HZ30E Product Video www.regency-fire.com WARNING FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury, death, or property damage.
  • Page 2: Manufactured Mobile Home Requirements

    Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, in the Untied States, or the Standard for Installation in Mobile Homes, CAN/CSA Z240 MH, in Canada. | Regency Horizon ® HZ30E-10 Gas Fireplace...
  • Page 3 To the New Owner: Congratulations! You are the owner of a state-of-the-art Gas Fireplace by REGENCY . The HZ30E has been designed to provide you with ® all the warmth and charm of a fireplace at the flick of a switch. The model HZ30E has been approved by Warnock Hersey/ Intertek for both safety and efficiency.
  • Page 4: Table Of Contents

    Rigid Pipe 4" x 6-5/8 " ............31 General Vent Maintenance .............55 Unit Installation with Horizontal Termination ......33 Valve assembly Replacement ..........56 4" x 6-5/8" venting ..............33 Main Assembly ...............58 Accessories ................60 Warranty .................63 | Regency Horizon ® HZ30E-10 Gas Fireplace...
  • Page 5 This is a copy of the label that accompanies each HZ30E-NG10 and HZ30E-LP10 Direct Vent Gas Fireplace. We have printed a copy of the contents here for your review. NOTE: Regency units are constantly being ® improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.
  • Page 6: For The State Of Massachusetts Only

    (e) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipm ent, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation. | Regency Horizon ® HZ30E-10 Gas Fireplace...
  • Page 7: Unit Dimensions

    UNIT DIMENSIONS FACEPLATE AND DOOR FRAME DIMENSIONS 33-1/4” (845mm) 32-3/8” (822mm) 25” (635mm) 24-7/8” (631mm) 27-5/8” (702mm) Verona / 4 Piece Faceplate Inner / Outer Faceplate ® Regency Horizon HZ30E-10 Gas Fireplace |...
  • Page 8: Important Message

    National Electrical Code, ANSI/NFPA 70 or CSA C22.1 Canadian Electrical Code. 3. See general construction and assembly instructions. The appliance and vent should be enclosed. | Regency Horizon ® HZ30E-10 Gas Fireplace...
  • Page 9: Installation Checklist

    14. Final check. Flat on Wall Corner Recessed into Wall/Alcove Before leaving this unit with the customer, the Corner installer must ensure that the appliance is firing correctly and operation fully explained to customer. ® Regency Horizon HZ30E-10 Gas Fireplace |...
  • Page 10: Clearances

    Caution Requirements The top, back and sides of the fireplace are defined by standoffs. The metal ends of the standoff may NOT be recessed into combustible construction. Alcove | Regency Horizon ® HZ30E-10 Gas Fireplace...
  • Page 11: Mantel Clearances

    "High Quality" or the paint may discolour. MANTEL LEG CLEARANCES Combustible mantel leg clearances as per diagram: 2 (51mm) MANTEL LEG Non-Combustible 1.5" (38mm) 5-1/2 (140mm) Allowable mantel leg projection 8 (203mm) 11 (279mm) ® Regency Horizon HZ30E-10 Gas Fireplace |...
  • Page 12: Unit Assembly Prior To Installation

    3. Install any optional components with access panel removed. Screw Locations 4. Reinstall access panel with 2 screws - prior to installing any facing material Note: Access panel is no longer accessible once facing material installed. Installation Access Panel | Regency Horizon ® HZ30E-10 Gas Fireplace...
  • Page 13: Wall Mount On / Off Switch And Receiver Installation

    11. Using the two (2. screws provided secure the cover plate to the Receiver. Low Voltage Junction Box J-Box Receiver Slider Switch Wall Plate 12 pin connector - located on outer right side of the firebox. ® Regency Horizon HZ30E-10 Gas Fireplace |...
  • Page 14: Framing Dimensions

    Framing depth measurement is noted with the nailing strips set as far forward on the firebox as possible. The nailing strips can be adjusted back up to 3-1/8” to allow for varying thicknesses in non-combustible material & wall finishes. | Regency Horizon ® HZ30E-10 Gas Fireplace...
  • Page 15: Optional Framing Kit

    4. Attach both vertical studs (285-025) and secure using 6 screws (2 at bottom, 2 at top and 2 on sides) as shown. Horizontal NOTE: Ensure the flat side of the steel stud is facing the wood framing. stud (285-026) ® Regency Horizon HZ30E-10 Gas Fireplace | Flat side out (285-025)
  • Page 16: Framing & Finishing

    Important: 1/2" gap required between faceplate and finished wall when using part #318-924, 318-927, 316- 951, 316-955 (4 pc. faceplate Verona surround). When using part # 316-934 and 316-937 (outer faceplate) the 1/2" gap is not necessary. | Regency Horizon ® HZ30E-10 Gas Fireplace...
  • Page 17: Non-Combustible Requirements

    3-1/8" 0" (flush) application, Regency is unable to guarantee the life of the joint compounds, paint or any Finished material other finish materials or workmanship applied to or used in any application surrounding the fireplace.
  • Page 18: Exterior Vent Termination Requirements

    * Clearance in accordance with local installation codes and the requirements of the gas supplier 3 feet (91cm) within a height of 15 feet (4.5m) above the meter / regulator assembly 3 feet (91cm) above - if within 10 feet (3m) horizontally | Regency Horizon ® HZ30E-10 Gas Fireplace...
  • Page 19: 4" X 6-5/8" Rigid Pipe

    4” X 6- 5/8” RIGID PIPE CROSS REFERENCE CHART Components from different Manufacturers may not be mixed. Not All Rigid Pipe components are available directly from FPI. Components from different Manufacturers may not be mixed. Not all rigid pipe components are available directly from Regency. Description...
  • Page 20 Never allow the vent to run downward - this could cause high temperatures and may present a possible fi re hazard. Regency Fireplace Products . 6988 Venture St. . Delta, BC . Canada . V4G 1H4 . 604-946-5155 . www.regency-fi re.com | Regency Horizon ®...
  • Page 21: Vent Restrictor Position

    4. Once the vent restrictor plate is in the required position, secure with screws. SET 0 (Factory set) VENT RESTRICTOR AT 1-3/4" 1-3/4" SET 1 THIS HOLE SETS THE VENT RESTRICTOR AT 1-1/4" 1-1/4" SET 2 THIS HOLE SETS THE VENT RESTRICTOR AT 3/4" 3/4" ® Regency Horizon HZ30E-10 Gas Fireplace |...
  • Page 22: Venting Introduction

    Refer to the "Vent Restrictor Position" section for details on how to change the vent restrictor from the factory setting of Set 0 to Set 1 if required. Note: For horizontal terminations the Regency Direct Vent Flex System may be used for installations with a maximum continuous vent length of up to 10 feet.
  • Page 23: Horizontal Terminations

    S.S. screws #8 x 1-1/2” drill point Notes: 1. Liner sections should be continuous without any joints or seams. 2. Only Flex pipe purchased from Regency may be ® used for Flex installations 3. Horizontal vent must be supported every 3 feet.
  • Page 24: Horizontal Terminations

    Metal Products Ameri Vent Direct Vent, Security Secure Vent ® , ICC Excel, Selkirk Direct-Temp. AstroCap is a proprietary trademark of FPI Fireplace Products International Ltd. Dura-Vent® and Direct Vent are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc. | Regency Horizon ® HZ30E-10 Gas Fireplace...
  • Page 25: Horizontal Terminations

    With the above options, maximum total pipe length if 37 feet with minimum of 6 feet total vertical and maximum 17 feet total horizontal. Please note minimum 1 foot between 90 elbows is required. Please note the minimum centerline for basic install shown above. ® Regency Horizon HZ30E-10 Gas Fireplace |...
  • Page 26 4' Min. 6' Max. Please note minimum 4' Max. 6' Min. 7' Max. 1 foot between 90 elbows is required. 5' Max. 8' Min. 8' Max. Restrictor Position - Set 0 (factory setting) | Regency Horizon ® HZ30E-10 Gas Fireplace...
  • Page 27 1 fo o t 6' Min. 5' Max. 10' Min. 8' Max. between 90 elbows is required. 7' Min. 6' Max. 12' Min. 9' Max. Restrictor Position - Set 0 (factory setting) ® Regency Horizon HZ30E-10 Gas Fireplace |...
  • Page 28: Venting Arrangement For Vertical Terminations

    Refer to the "Vent Restrictor Position" section for details on how to change the vent restrictor from the factory setting of Set 0 to Set 1 or Set 2 if required. Vent Restrictor on Set 2 Vent Restrictor on Set 1 | Regency Horizon ® HZ30E-10 Gas Fireplace...
  • Page 29: Venting Arrangements - Vertical Terminations

    Horizontal Distance (Feet) Horizontal Distance (Feet) Horizontal Distance (Feet) The shaded area in the diagrams show the allowable vertical terminations when using two- 3" co-linear aluminium flex and 4 x 6-5/8" rigid pipe. ® Regency Horizon HZ30E-10 Gas Fireplace |...
  • Page 30: Vertical Termination With Co-Linear Flex System

    3" Co-linear Adapter with flashing Outer Pipe with Kit# 946-563 Air Intake Pipe Length Co-Linear Flex Rigid Pipe Adapter Adapter # 510-994 with Kit# 946-563 45 Elbow Inner Pipe Adapter with Kit# 946-563 | Regency Horizon ® HZ30E-10 Gas Fireplace...
  • Page 31: Vertical Terminations

    5' Max. 5' Min. elbows is required. required. 5' Min. 8' Max. 6' Min. 6' Max. 6' Min. Restrictor Position - Set 0 (factory setting) Restrictor Position - Set 0 (factory setting) ® Regency Horizon HZ30E-10 Gas Fireplace |...
  • Page 32 6' Max. 8' Min. horizontal. Please note min. 1 6' Min. 7' Max. 9' Min. foot between 90 7' Min. 8' Max. 10' Min bows is required. Restrictor Position - Set 0 (factory setting) | Regency Horizon ® HZ30E-10 Gas Fireplace...
  • Page 33: Unit Installation With Horizontal Termination

    3 supplied screws (drilling pilot holes will make this easier). 4. Level the fireplace and fasten it to the framing Diagram 2 using nails or screws through the top and side nailing strips. Diagram 7 Diagram 1 ® Regency Horizon HZ30E-10 Gas Fireplace |...
  • Page 34: Unit Installation With Horizontal Termination

    Wall Thimble 2 pieces Pac to the outer flex pipe and slip it over the (10" (254mm) Outer Diameter) outer flue collar of the vent terminal at least 1-3/8"(35mm) and fasten with the 3 screws. | Regency Horizon ® HZ30E-10 Gas Fireplace...
  • Page 35: Dura-Vent Horizontal Termination

    “Mill-Pac” kel upside sealant (supplied) to every inner pipe connec- down. tion. Failure to do so may result in drafting or performance issues not covered under warranty. ® Regency Horizon HZ30E-10 Gas Fireplace |...
  • Page 36: Unit Installation With Vertical Termination

    8. Install the vertical termination cap by twist- locking it. Note: Any closets or storage spaces, which the vent passes through must be enclosed. Diagram 2 | Regency Horizon ® HZ30E-10 Gas Fireplace...
  • Page 37: High Elevation

    Orifice Size #57 DMS Maximum Input 13,000 Btu/h Note: If you have an incorrect flame pattern, (3.81 kW) contact your Regency dealer for further ® instructions. Incorrect flame pattern will have small, probably yellow flames, not coming into proper contact HIGH ELEVATION with the rear burner or flame sensor.
  • Page 38: Wiring Diagram

    1 of 10 CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. | Regency Horizon ® HZ30E-10 Gas Fireplace...
  • Page 39: Optional Fan Installation

    These fans collect a lot of dust from within your home. Ensure you maintain these fan motors on a regular basis by vacuuming the fan blades and the housing with a soft brush nozzle. ® Regency Horizon HZ30E-10 Gas Fireplace |...
  • Page 40 10. Attach the green ground wire to the ground lug – located in the lower back corner of the unit. 6. Remove the valve access plate by removing the 17 outer screws – see locations below | Regency Horizon ® HZ30E-10 Gas Fireplace...
  • Page 41 Fan Control Module marked “COM”. Turn the switch on the Fan Control Module to the ON position. ON is to the left. The “O” is the off position ® Regency Horizon HZ30E-10 Gas Fireplace |...
  • Page 42: Proflame Remote System Gtmf With Optional Fan

    CAUTION: Label all wires prior to disconnection Caution: Ensure that the wires do not touch any when servicing controls. Wiring errors can cause hot surfaces and are away from sharp edges. improper and dangerous operation. | Regency Horizon ® HZ30E-10 Gas Fireplace...
  • Page 43: Optional Wall Thermostat Installation

    - see picture below. NOTE: When the remote receiver is set to ON position, the remote control transmitter and all of its features are now disabled. CAUTION Do not wire Thermostat wires to 120V wire. ® Regency Horizon HZ30E-10 Gas Fireplace |...
  • Page 44: Reflective Panel Installation

    5) Reinstall glass door - reinstall faceplate. 3) Install the left side panel - secure in position with one panel clip and 6) Final installation one screw, as shown in the diagram below. | Regency Horizon ® HZ30E-10 Gas Fireplace 05/16/13...
  • Page 45: Glass Crystals Or Optional Stones

    Pebbles HZ30E 2lbs 2lbs 1 package (3 x bags pebbles) Natural River Pebbles shown surrounding the Horizon Burner Glass Crystals shown surrounding the Burner Optional Volcanic Stones + Glass Crystals shown on burner. ® Regency Horizon HZ30E-10 Gas Fireplace |...
  • Page 46: Optional Log Set Installation

    4. Position Log 3, line up bottom pin landing on Log 3 with pin on Log 1. The remainder of Log 3 will rest on the burner tray. Log clips installed HZ30E HZ30E use top pin landing HZ30E shown - Log 3 install | Regency Horizon ® HZ30E-10 Gas Fireplace...
  • Page 47 6. Place lava embers/rocks on glass - ensure rocks do not block pilot. Do not place lava rocks/embers too close to logs as this may cause carboning. 7. Adjust aeration, see unit manual for setting. HZ30E shown - Final Install ® Regency Horizon HZ30E-10 Gas Fireplace | 919-265a 06.10.14...
  • Page 48: Glass Door Installation

    See Diagram 2. Diagram 3 Diagram 1 Hook top of door onto top flange Flush Door Diagram 2 | Regency Horizon ® HZ30E-10 Gas Fireplace...
  • Page 49: Safety Screen / Inner Door Frame Removal/Installation

    2. Install safety screen (2) into inner door frame (3). Secure screen by bending down the 6 tabs as shown Tabs 5. Attach completed assembly to the glass door on the unit. 919-450 02.12.15 ® Regency Horizon HZ30E-10 Gas Fireplace |...
  • Page 50: Outer Door Frame Installation

    Inner door frame may be installed by itself, or with the outer door frame. The outer door frame cannot be installed by it- self - if installing the outer door frame - the inner door frame must also be installed. | Regency Horizon ® HZ30E-10 Gas Fireplace...
  • Page 51: Verona / 4 Piece Faceplate Installation

    - up to 1/2". 3-1/8" 76mm Important: 1/2" gap required between faceplate and fi nished wall. +1/2" +1/4" Use fi rst notch in bracket for standard installation Final Install ® Regency Horizon HZ30E-10 Gas Fireplace | 919-073a 05/16/12...
  • Page 52: Operating Instructions

    Use a non-abrasive cleaner and DO NOT ATTEMPT TO CLEAN THE GLASS WHILE IT IS HOT. | Regency Horizon ® HZ30E-10 Gas Fireplace...
  • Page 53: Lighting Procedure

    1. Turn the wall mounted switch or remote to the "OFF" position. Button 2. Press "OFF" on the remote control. 3. Turn the gas control knob to the "OFF" position to turn off the pilot. Diagram 2 Remote shown in Manual Mode on Hi ® Regency Horizon HZ30E-10 Gas Fireplace |...
  • Page 54: Copy Of Lighting Plate Instructions

    Utilisez l'interrupteur murale ON/OFF du Brûleur ou du contrôle à distance pour éteindre le brûleur. Si le service est effectuée–vous devez débrancher l'alimentation et coupez le gaz à l'unité. DO NOT REMOVE THIS INSTRUCTION PLATE 919-401a | Regency Horizon ® HZ30E-10 Gas Fireplace...
  • Page 55: Maintenance Instructions

    * Do not clean when the glass is hot. paint and should only be refinished with heat such as water droplets forming in the inner * The use of substitute glass will void all product resistant paint. Regency uses StoveBright ® liner, and subsequently dripping out the joints, warranties.
  • Page 56: Valve Assembly Replacement

    * Prior to removing burner - remove crystals, pebbles, spa stones and inner panels - if installed. Location of screws on access plate 6. Loosen 2 screws at the back of the burner to release it. | Regency Horizon ® HZ30E-10 Gas Fireplace...
  • Page 57 7. Partially lift out valve tray - use extreme caution, the thermodisc needs to be removed before valve tray is lifted out completely. Thermodisc 8. Disconnect the inlet gas line and remove the valve assembly. 9. Replace valve assembly and reverse steps. ® Regency Horizon HZ30E-10 Gas Fireplace |...
  • Page 58: Main Assembly

    Pilot Orifice LP 919-362 Manual 911-037 Flame sensor 911-038 Flame Electrode 911-039 2 flame pilot hood 911-137 Pilot Clip 910-432 Pilot Tube 910-142 Fan Thermodisc W840470 Pilot Assembly Gasket 904-658 Inlet gas flex line SS | Regency Horizon ® HZ30E-10 Gas Fireplace...
  • Page 59 | 59 ® Regency Horizon HZ30E-10 Gas Fireplace |...
  • Page 60: Accessories

    Sangria Luster Firebeads 316-955 Verona Glass Surround Part # Description 946-737 Glacier Ice Firebeads Chocolate Brown 946-675 Black Reflective Crystals 946-738 Caramel Luster Firebeads 946-676 Copper Crystals 258-900 Steel Stud Framing Kit 946-677 Starfire Crystals | Regency Horizon ® HZ30E-10 Gas Fireplace...
  • Page 61 | 61 ® Regency Horizon HZ30E-10 Gas Fireplace |...
  • Page 62 | Regency Horizon ® HZ30E-10 Gas Fireplace...
  • Page 63: Warranty

    Conditions: Any part or parts of this unit which in our judgement show evidence of such defects will be repaired or replaced at Regency's option, through an accredited distributor or agent provid- ed that the defective part be returned to the distributor or agent Transportation Prepaid, if requested.
  • Page 64 Installer: ___________________________________________________________ Phone #: ___________________________________________________________ Date Installed: ______________________________________________________ Serial No.: __________________________________________________________ Horizon HZ30E Video Regency Horizon and SureFire are trademarks of FPI Fireplace Products International Ltd. Printed in Canada © Copyright 2015 FPI Fireplace Products International Ltd. All rights reserved.

This manual is also suitable for:

Horizon hz30e-lp10Horizon hz30e

Table of Contents