VENTING ARRANGEMENTS

HORIZONTAL TERMINATION (FLEX)

Regency
Direct Vent System
®
These venting systems, in combination with the HZ54E, have been tested and listed as a direct vent system by Warnock Hersey/Intertek. The location of the
termination cap must conform to the requirements in the Vent Terminal Locations diagram from the "Exterior Vent Termination Locations" section.
FPI Direct Vent (Flex) System Termination Kits include all the parts needed to install the HZ54E using a flexible vent.
FPI Kit #
Length Contains:
#946-615
4 Feet
1)
2)
3)
4)
#946-618
6 Feet
5)
6)
7)
#946-616
10 Feet
8)
9)
10) vinyl siding standoff
5" dia. flue pipe
8" dia.
Flue pipe
20 |
®
Regency Horizon
HZ54E-10 Gas Fireplace
8" flexible liner (Kit length)
5" flexible liner (Kit length)
spring spacers
thimble
AstroCap termination cap
screws
tube of Mill Pac
plated screws
S.S. screws #8 x 1-1/2" drill point
Wall Thimble
(Mandatory in all
Horizontal T erminations)
Vinyl Siding
Standoff
AstroCap XL
Termination Cap
(Part #946-623/P)
spring spacer
Vent Guard - if required*
(Part #946-506/P)
TM
Notes:
1) Liner sections should be continuous without any joints
or seams.
2) Only Flex pipe purchased from FPI may be used for Flex
installations.
3) Horizontal vent must be supported every 3 feet.
4) A wall thimble is mandatory for all horizontal terminations
due to high temperatures.