installation
|
34

AERATION ADJUSTMENT

The burner aeration is factory set but may need adjusting due to either the local gas supply or altitude. Open the air shutter for a blue flame or close for a
more yellow flame.
For instructions to remove the burner for access to
the ventury cap, see pages 46-47 in this manual.
Minimum Air Shutter Opening:
NG
1/2"
34 |
®
Regency Horizon
HZ54E-10 Gas Fireplace
NG with Logs
Full open
NG with Stones
Full open
LP
1/2"
LP with Logs
Full open
LP with Stones
Full open
CAUTION: Carbon will be produced if air shutter
is tightly closed.
Note: Any damage due to carboning
resulting from improperly setting
the aeration controls is NOT covered
under warranty.
Venturi Cap