HZ54E-LP UNIT

1) Loosen 6 screws that secure the burner extenders. on burner tray,
located behind the burner on either side of the pilot assembly.
2) Lift out the 2 burner tray extenders.
Burner tray
Burner tray extenders
4) After extenders have been removed. Remove the 2 screws that
secure the burner tray, at the base of the firebox.
5) Slide the burner to the left and lift it out.
Location of screws securing burner
Burner Bracket
6) With burner removed - lift out burner tray.
56 |
®
Regency Horizon
HZ54E-10 Gas Fireplace
Burner tray extenders
7) Disconnect the green and orange wires from the valve.
Green Wire
8) Disconnect the green ground wire from the valve bracket.
9) Remove the valve tray by undoing 12 screws.
10) Partially lift out valve tray.
11) Disconnect the inlet gas line.
12) Replace valve and reverse steps.
Orange Wire
Green ground wire