Regency Horizon HZ54-NG Owners & Installation Manual

Hide thumbs Also See for Horizon HZ54-NG:
Table of Contents

Advertisement

Quick Links

Regency Horizon
www.regency-fi re.com
WARNING:
If the information in these instructions are not followed exactly,
a fi re or explosion may result causing property damage,
personal injury or loss of life.
FOR YOUR SAFETY
Do not store or use gasoline or other fl ammable vapors and
liquids in the vicinity of this or any other appliance.
Installation and service must be performed by a qualifi ed
installer, service agency or the gas supplier.
Tested by:
918-751b
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
Gas Fireplace
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
HZ54
FOR YOUR SAFETY
What to do if you smell gas:
 Do not try to light any appliance
 Do not touch any electrical switch:
do not use any phone in your
building.
 Immediately call your gas supplier
from a neighbour's phone. Follow
the gas supplier's instructions.
 If you
supplier, call the fi re department.
Owners &
Installation Manual
MODELS: HZ54-NG Natural Gas
HZ54-LP Propane
cannot reach your gas
10/08/09

Advertisement

Table of Contents
loading

Summary of Contents for Regency Horizon HZ54-NG

  • Page 1 Owners & Regency Horizon HZ54 ™ Installation Manual Gas Fireplace MODELS: HZ54-NG Natural Gas HZ54-LP Propane www.regency-fi re.com WARNING: FOR YOUR SAFETY If the information in these instructions are not followed exactly, What to do if you smell gas:  Do not try to light any appliance a fi...
  • Page 2 WARNING HOT GLASS WILL CAUSE BURNS DO NOT TOUCH GLASS UNTIL COOLED NEVER ALLOW CHILDREN TO TOUCH GLASS CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERATURES, ESPECIALLY THE FIREPLACE GLASS, AND SHOULD STAY AWAY TO AVOID BURNS OR CLOTHING IGNITION.
  • Page 3: Manufactured Mobile Home Requirements

    To the New Owner: Congratulations! ® You are the owner of a state-of-the-art Gas Fireplace by REGENCY . The HZ54 has been designed to provide you with all the warmth and charm of a wood fi replace at the fl ick of a switch.
  • Page 4: Table Of Contents

    Unit Installation with Horizontal Termination ....26 Unit Installation with Vertical Termination ....27 The Warranty: Limited Lifetime ........51 Unit Installation ............28 Horizontal Termination .........28 with Flex Vent System .........28 High Elevation .............29 Gas Line Installation ............29 HZ54 Regency Horizon Gas Fireplace...
  • Page 5: Safety Label

    The State of Massachusetts requires the installation of a carbon monoxide alarm in accordance with NFPA 720 and a CO alarm with battery back up in the same room where the gas appliance is installed. HZ54 Regency Horizon Gas Fireplace...
  • Page 6: Requirements

    (e) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation. HZ54 Regency Horizon Gas Fireplace...
  • Page 7: Dimensions

    DIMENSIONS UNIT DIMENSIONS FACEPLATE & DOOR FRAME OVERLAY DIMENSIONS HZ54 Regency Horizon Gas Fireplace...
  • Page 8: Installation

    9) Wear gloves and safety glasses for protection ALERTED TO THE HAZARDS OF HIGH while doing required maintenance. SURFACE TEMPERATURES, ESPE- CIALLY THE FIREPLACE GLASS, AND SHOULD STAY AWAY TO AVOID BURNS OR CLOTHING IGNITION. HZ54 Regency Horizon Gas Fireplace...
  • Page 9: Installation Checklist

    Before leaving this unit with the customer, the installer must ensure that the appliance is fi ring Flat on Wall correctly and operation fully explained to Flat on Wall Corner customer. Recessed into Wall/Alcove Corner HZ54 Regency Horizon Gas Fireplace...
  • Page 10: Clearances

    F: Alcove Depth 36" (914mm) Front to Back Wall (Maximum) G: To Floor 28 - 7/8" (733mm) Top of Fireplace Opening Note 0" No hearth required Installed Close Installed Close to Ceiling to Floor NON-COMBUSTIBLE REQUIREMENTS HZ54 Regency Horizon Gas Fireplace...
  • Page 11: Top Non-Combustible Facing Board

    Note: In addition to the top piece of non-combustible board other non-combustible boards will be required to complete this Non-combustible board installation. These materials can be found at most building MUST BE PRIMED. supply stores. HZ54 Regency Horizon Gas Fireplace...
  • Page 12: Mantel Clearances

    Top of Fireplace 28-1/8” Opening To Unit Base Legs MANTEL LEG CLEARANCES Combustible mantel leg clearances as per diagram: 4”(102mm) MANTEL LEG Non-Combustible 1.5" (38mm) 5-1/2” (140mm) Allowable mantel leg projection 8” (203mm) 11” (279mm) HZ54 Regency Horizon Gas Fireplace...
  • Page 13: Framing & Finishing

    1” Forward removal of the faceplate. Unit 1" 1/2" Nailing Strip ½” Forward Unit 1-1/2" 0" (fl ush) Nailing Strip Flush w/unit Factory Set Unit HZ54 Regency Horizon Gas Fireplace...
  • Page 14 Dangerous operating conditions will occur if minimum framing dimensions are not adhered to. Metal Stud (Header) on edge Metal Stud (Header) on edge Non-Combustible Facing (Located on the right side of the fireplace) HZ54 Regency Horizon Gas Fireplace...
  • Page 15: Unit Assembly Prior To Installation

    Each direct vent gas appliance must use it's own separate vent system. Common vent systems are prohibited. Remove this screw to release top standoff / nailing Standoff strip Diagram 2 HZ54 Regency Horizon Gas Fireplace...
  • Page 16: Vent Restrictor Position

    Vent Restrictor Set 2 Vent Restrictor Set 3 2” 1” SET 3 THIS HOLE SETS THE SET 4 VENT RESTRICTOR THIS HOLE SETS THE AT 2” VENT RESTRICTOR AT 1” Vent Restrictor Set 3 Vent Restrictor Set 4 HZ54 Regency Horizon Gas Fireplace...
  • Page 17: Exterior Vent Termination Requirements

    * Clearance in accordance with local installation codes and the requirements of the gas supplier 3 feet (91cm) within a height of 15 feet (4.5m) above the meter / regulator assembly 3 feet (91cm) above - if within 10 feet (3m) horizontally HZ54 Regency Horizon Gas Fireplace...
  • Page 18: Venting Arrangements

    2) Only Flex pipe purchased from FPI may be used for Flex installations. 3) Horizontal vent must be supported every 3 feet. 4) A wall thimble is mandatory for all horizontal terminations due to high temperatures. HZ54 Regency Horizon Gas Fireplace...
  • Page 19: Rigid Pipe Venting Systems

    FPI venting systems as well as Simpson Dura-Vent Direct Vent Pro, ICC Excel and Selkirk Direct-Temp. AstroCap XL is a proprietary trademark of FPI Fireplace Products International Ltd. Dura-Vent® and Direct Vent are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc. HZ54 Regency Horizon Gas Fireplace...
  • Page 20: 5" X 8" Rigid Pipe Cross Reference Chart

    5DWS Offset Support 58DVA-ES - N/A from FPI 5DT-OS Wall Thimble-Black 58DVA-WT 5DT-WT 5DWT TE-5DE90 Wall Thimble Support/Ceiling Support 58DVA-DC TE-5DE90B - N/A from FPI Firestop Spacer 58DVA-FS 5DT-FS 5DFS Trim Plate-Black 58DAV-WFS 5DT-TP 5DCP HZ54 Regency Horizon Gas Fireplace...
  • Page 21 1 foot of run towards the termination. 36” (914mm) 29-13/16” (757mm) 39-7/16” (1002mm) Never allow the vent to run downward - this could cause high temperatures and may present a possible fi re hazard. 48” (1219mm) 38-1/4” (972mm) 47-7/8” (1216mm) HZ54 Regency Horizon Gas Fireplace...
  • Page 22: Venting Arrangements

    Firestops are required at each fl oor level and whenever passing through a wall. through a wall. • A wall thimble is mandatory for all horizontal terminations due • A wall thimble is mandatory for all horizontal terminations due to to high temperatures. high temperatures. HZ54 Regency Horizon Gas Fireplace...
  • Page 23 Please note min. 1 foot 5' Min. 4' Max. 10' Min. 7' Max. between 90 elbows is 6' Min. 6' Max. 11' Min. 9' Max. required. VENT RESTRICTOR SETTING: Vent restrictor factory set at Set 1, no adjustment required. HZ54 Regency Horizon Gas Fireplace...
  • Page 24 Please note min. 1 foot 5' Min. 6' Max. 8' Min. between 90 elbows is 6' Min. 8' Max. 9' Min. required. VENT RESTRICTOR SETTING: Vent restrictor factory set at Set 1, no adjustment required. HZ54 Regency Horizon Gas Fireplace...
  • Page 25: Venting Arrangements

    Set 1 to Set 2 or Set 3 if required. Note: Must use optional fl ue adaptor when using Rigid Pipe (Part # 770-994). Max. 10’ (3m)(centerline to centerline) Minimum length of pipe between elbows 12” (305mm) HZ54 Regency Horizon Gas Fireplace...
  • Page 26: Venting Arrangements

    Set 1 to Set 3 or Set 4 if required. Note: Must use optional fl ue adaptor when using Rigid Pipe (Part # 770-994). Max. 10’ (3m)(centerline to centerline) Minimum length of pipe between elbows 12” (305mm) HZ54 Regency Horizon Gas Fireplace...
  • Page 27: Unit Installation With Horizontal Termination

    The location of the horizontal vent RTV) is optional. termination on an exterior wall must meet all local and national building codes, and must not be blocked or obstructed. See "Exterior Vent Termination Locations" section for more details. Diagram 7 HZ54 Regency Horizon Gas Fireplace...
  • Page 28: Unit Installation With Vertical Termination

    fl ashing until the height of the vent cap meets the minimum height requirements specifi ed in Diagram 5 or local codes. Note that for steep roof pitches, the vertical height must be increased. Diagram 3 HZ54 Regency Horizon Gas Fireplace...
  • Page 29: Unit Installation

    1-3/8"(35mm) and fasten with the 3 screws. NOTE: Horizontal sections must be sup- ported at intervals not exceeding 3 feet (0.9 meter). (Flame picture and performance will be affected by sags in the liner). HZ54 Regency Horizon Gas Fireplace...
  • Page 30: High Elevation

    GAS LINE Note: If you have an incorrect fl ame pattern, INSTALLATION ® contact your Regency dealer for further instructions. Since some municipalities have additional Incorrect fl ame pattern will have small, local codes it is always best to consult with probably yellow fl...
  • Page 31: Aeration Adjustment

    Caution: Ensure that the wires do not touch any CAUTION: Label all wires prior to disconnection hot surfaces and are away from sharp edges. when servicing controls. Wiring errors can cause improper and dangerous operation. HZ54 Regency Horizon Gas Fireplace...
  • Page 32: Optional Wall Thermostat

    18 GA. 20 Ft. 20 GA. 12 Ft. 22 GA. 9 Ft. Note: Regency Profl ame systems include a white and black wall cover & switch. GTM/GTMF remote controls are not available for this unit. HZ54 Regency Horizon Gas Fireplace...
  • Page 33: Gt Remote Wiring Diagram

    12. Using the two (2) screws provided secure the cover plate to the Receiver. J-Box Receiver Slider Switch Wall Plate REFER TO CODING INSTRUCTIONS IN THIS MANUAL Extra wires not used spade connectors Green wire Red wire White wire Black wire HZ54 Regency Horizon Gas Fireplace...
  • Page 34: Optional Log Set Installation

    3) Pin clips are attached to the lip edge of the bottom cover (not the burner) see diagrams 3 & 4. Measurements to centre of pins. Burner Bottom Cover Side measurements Lip Edge from corner edge. HZ54 Regency Horizon Gas Fireplace...
  • Page 35 4) Install the glass crystals (see glass crystal installation section in this manual). Diagram 6 5) Place platinum embers on glass crystals as shown in diagram 7. Diagram 7 6) If installing optional pebbles - install pebbles before log installation. Diagram 8 HZ54 Regency Horizon Gas Fireplace...
  • Page 36 Note: Logs should be oriented exactly as shown in diagram 10. Diagram 10 9) Install the following: a) *Glass door b) *Faceplate and door frame *Refer to these sections in the HZ54 manual for detailed instructions. Log Set Installed (shown with optional pebbles) Diagram 11 HZ54 Regency Horizon Gas Fireplace...
  • Page 37: Optional Refl Ective Panel Installation

    Left Side Bracket Fit side panel tab into slot Right side back panel tab fi tted into slot Left side panel in position Bracket shown in place on right side of the fi rebox HZ54 Regency Horizon Gas Fireplace...
  • Page 38: Glass Crystals Or Optional Ceramic Stones

    For units P33S, L676S, U32S, E33S only Optional Ceramic Stones + Glass Crystals shown on burner. Optional Ceramic Stones shown on burner. For Units HZ54, HZ42 ST, HZ42 only For units P33S, L676S, U32S, E33S only HZ54 Regency Horizon Gas Fireplace...
  • Page 39 Glass Crystals or optional Ceramic Spa Stones. NOTE: Only the supplied and approved pebbles / crystals are to be used. White River Pebbles shown surrounding the Burner Natural River Pebbles shown surrounding the Burner Glass Crystals shown surrounding the Burner HZ54 Regency Horizon Gas Fireplace...
  • Page 40: Faceplate & Door Frame Overlay Installation

    Magnet Position 2) Place 2 of the supplied magnets on the lower corners of the Door Frame Overlay, this will keep the Faceplate in postion after it has been installed. HZ54 Regency Horizon Gas Fireplace...
  • Page 41 fi nishing that protrudes slightly beyond the faceplate. sliding the plate up or down as required. Faceplate Mounting Slots First Mounting Slot (recommended) Completed Faceplate & Door Frame Overlay Installation HZ54 Regency Horizon Gas Fireplace...
  • Page 42: Operating Instructions

    Use a non-abrasive 3) Turn the gas control knob to the "OFF" posi- cleaner and DO NOT ATTEMPT TO CLEAN tion to turn off the pilot. THE GLASS WHILE IT IS HOT. HZ54 Regency Horizon Gas Fireplace...
  • Page 43: Copy Of Lighting Plate Instructions

    3) Turn off all electric power to the appliance if service is to be performed. You may shut off the pilot during prolonged non use periods to conserve fuel. DO NOT REMOVE THIS INSTRUCTION PLATE 918-583 HZ54 Regency Horizon Gas Fireplace...
  • Page 44: Maintenance

    * The use of substitute glass will void all product paint and should only be refi nished with heat 3) Check for evidences of excessive warranties. resistant paint. Regency ® uses StoveBright condensation, such as water droplets forming * Care must be taken to avoid breakage of the Paint - Metallic Black #6309.
  • Page 45: Glass Door Removal

    3) Remove the faceplate by lifting it up off the hinges on the sides of the fi rebox. b) Swing the door out 45 from the bottom and lift up and out. 4) Remove the door frame overlay by swinging out 45 from the bottom and lift up and out. HZ54 Regency Horizon Gas Fireplace...
  • Page 46: Dc Spark Box Battery Replacement

    4) Remove the battery cover from the DC Spark Box. DC Spark Box Bracket Assembly 5) Remove the AA battery and replace with a removed from fi rebox. new one. 6) Reverse steps 4 to 1. HZ54 Regency Horizon Gas Fireplace...
  • Page 47: Valve Tray Replacement

    Note: See next pages for specifi c instructions for NG / LP units. 4) Remove the door frame overlay by swinging out 45 from the bottom and lift up and out. HZ54 Regency Horizon Gas Fireplace...
  • Page 48: Hz54-Ng Unit

    8) Disconnect the ON/OFF connector wires from the valve. 12) Partially lift out valve tray. 13) Disconnect the inlet gas line. ON/OFF Connector Wires 9) Disconnect the DC Sparker leads at the valve. 14) Replace valve and reverse steps. DC Sparker Lead HZ54 Regency Horizon Gas Fireplace...
  • Page 49: Hz54-Lp Unit

    Location of screws securing burner 14) Partially lift out valve tray. 15) Disconnect the inlet gas line. Burner Bracket 10) With burner removed - lift out burner tray. Gas Inlet Line 16) Replace valve and reverse steps. HZ54 Regency Horizon Gas Fireplace...
  • Page 50: Parts List

    Flue Collar Gasket 476-023 Plate Relief Gasket 476-055 Valve Tray Gasket 521-035 Inner Flue Collar Gasket 940-359/P Flush Glass 476-011 Flush Glass 910-882 Wire (Valve to Burner ON/OFF) 948-409 Flue Collar 948-415 Lifting Handle 918-751 Manual HZ54 Regency Horizon Gas Fireplace...
  • Page 51: Accessories

    946-671 Cobalt Blue Glass Crystals 946-672 Natural River Pebbles 946-673 White River Pebbles 946-674 Stones 476-930 Log Set 946-680 GT Profl ame Remote Control 910-576 Cover Wall Mount 910-572 Receiver GTM SIT w/Batt & Cover HZ54 Regency Horizon Gas Fireplace...
  • Page 52: Warranty

    Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit ® thoroughly before it leaves our facility. Fireplace Products is pleased to extend this limited lifetime warranty to the original purchaser of a Regency Regency Product. This warranty is not transferable.
  • Page 53 Installer: ___________________________________________________________ Phone #: ___________________________________________________________ Date Installed: ______________________________________________________ Serial No.: __________________________________________________________ Regency Horizon is a trademark of FPI Fireplace Products International Ltd. © Copyright 2009, FPI Fireplace Products International Ltd. All rights reserved. Printed in Canada HZ54 Regency Horizon Gas Fireplace...

This manual is also suitable for:

Horizon hz54-lpHorizon hz54

Table of Contents