Rigid Pipe Venting Systems - Regency Panorama P36D Owners & Installation Manual

Zero clearance direct vent gas fireplace
Hide thumbs Also See for Panorama P36D:
Table of Contents

Advertisement

installation
|
32

RIGID PIPE VENTING SYSTEMS

Horizontal or Vertical Terminations
The minimum components required for a basic
horizontal termination are:
1
Horizontal Termination Cap
1
90
Elbow
o
1
Rigid Pipe Adaptor
1
Wall Thimble
1
Length of pipe to suit wall thickness
(see chart)
Wall thickness is measured from the back standoffs
to the inside mounting surface of termination cap.
For siding other than vinyl furring strips may be used,
instead of the vinyl siding standoff, to create a level
surface to mount the vent terminal. The Terminal
must not be recessed into siding. Measure the wall
thickness including furring strips.
If a Vinyl Siding Standoff is required (it must be
used with vinyl siding), measure to outside surface
of wall without siding and add 2 inches.
Vertical
Termination
Cap
Storm Collar
Flashing
Ceiling Firestop
Pipe Length
The FPI AstroCap
and FPI Riser Vent terminal are certified for installations using FPI venting systems as well as Simpson Dura-Vent
TM
American Metal Products, Security Secure Vent
Ltd. Dura-Vent® and Direct Vent are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc.
32 |
®
Regency
P36D-10 Zero Clearance Direct Vent Gas Fireplace
Wall Thickness (inches)
Wall Thickness (inches)
Vinyl Siding
Standoff (Optional)
Wall Thimble
Adj.Pipe Length
11" - 14-5/8"
o
90 Elbow
24" Pipe
Length
Rigid Pipe Adaptor
, AmeriVent Direct Vent. AstroCap
®
Flat Wall Installation
4" - 5-1/2"
7" - 8-1/2"
10" - 11-1/2"
9" - 14-1/2"
15" - 23-1/2"
Corner Installation
3-1/4" - 6-3/4"
7-3/4" - 16-1/4"
7-1/4" - 8-3/4"
4-1/4" - 5-3/4"
Horizontal
Termination
Cap
WARNING:
Do not combine venting components from
different venting systems.
However use of the AstroCap
acceptable with all systems.
This product has been evaluated by Intertek for
using a Rigid Pipe Adaptor in conjunction with
DuraVent Direct Vent, Selkirk Direct-Temp, Ameri
Vent Direct venting and Security Secure Vent
systems. Use of these systems with the Rigid
Pipe Adaptor is deemed acceptable and does not
affect the Intertek WHI listing of components.
is the proprietary trademark of FPI Fireplace Products International
TM
Vent Length Required (inches)
6"
9"
12"
11" - 14-5/8" Adj. Pipe
17" - 24" Adj. Pipe
Vent Length Required (inches)
11" - 14-5/8" Adj. Pipe
17" - 24" Adj. Pipe
6" + 12"
9" + 9"
6" + 9"
Alternate
Horizontal
Termination
Caps
and FPI Riser is
TM
Direct Vent ,
®

Advertisement

Table of Contents
loading

This manual is also suitable for:

P36d-ng10P36d-lp10