Vent Restrictor Position - Regency Horizon HZ54E-NG10 Owners & Installation Manual

Hide thumbs Also See for Horizon HZ54E-NG10:
Table of Contents

Advertisement

installation
|
18

VENT RESTRICTOR POSITION

Vent restriction is required for certain venting installations, see the diagrams in the "Venting
Arrangements" section to determine if they are required for your installation.
The Vent Restrictor plate is located on the inside top of the firebox.
To set the vent restriction as indicated in the venting arrangements diagrams, refer to the following instructions;
1) Remove the glass door.
2) Remove the screws that hold the vent restrictor plate in place.
3) Adjust the vent restrictor plate to the required vent restrictor position as per the diagrams shown.
4) Once the vent restrictor plate is in the required position, secure with screws.
ent Restrictor Settings for HZ54E-NG
V
SET 1
THIS HOLE SETS THE
VENTR ESTRICTOR
(factory setting)
AT 4.25
SET 2
THIS HOLE SETS THE
VENTR ESTRICTOR
AT 3
SET 3
THIS HOLE SETS THE
VENTR ESTRICTOR
AT 2-1/2
SET 4
THIS HOLE SETS THE
VENTR ESTRICTOR
AT 2
18 |
®
Regency Horizon
HZ54E-10 Gas Fireplace
4.25
Vent Restrictor Set 1
Factory Set Vent Restrictor
(No adjustment required)
3
Vent Restrictor Set 2
2.5
Vent Restrictor Set 3
2
Vent Restrictor Set 4
ent Restrictor Settings for HZ54E-LP
V
SET 1
THIS HOLE SETS THE
VENT RESTRICTOR
(factory setting)
AT 4.25
SET 4
THIS HOLE SETS THE
VENT RESTRICTOR
AT 2
SET 5
THIS HOLE SETS THE
VENT RESTRICTOR
AT 1
4.25
V ent Restrictor Set 1
Factory Set V ent Restrictor
(No adjustment required)
2
Vent Restrictor Set 4
1
Vent Restrictor Set 5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Horizon hz54e-lp10

Table of Contents