Hopper - Epson Stylus NX510 Service Manual

Color inkjet printer
Hide thumbs Also See for Stylus NX510:
Table of Contents

Advertisement

Epson Stylus NX510/515/SX510W/515W/TX550W/NX415/SX410/415/TX410/419/NX215/SX210/215/TX210/213/219/ME OFFICE 510
3.
Release the Extension Spring 1.41 from the hook of the Main Frame.
4.
Rotate the CR Scale 90 degrees as shown in the figure and remove the scale
from the Main Frame.
90 degrees
Hook
Extension Spring 1.41
Figure 4-44. Removing the CR Scale (2)
When installing the CR Scale, pay attention to the following
instructions:
Chipped part of the CR Scale must face upward.
CR scale should be passed through the slit of the CR Encoder
Sensor.
Make sure that the Extension Spring 1.41 is not be twisted,
and then attach its end to the hook of the Main Frame.
DISASSEMBLY/ASSEMBLY
Chipped
CR Scale
Disassembling the Printer Mechanism

4.5.3 Hopper

Parts/Components need to be removed in advance
Document Cover/ASF Cover/Scanner Unit/Panel Unit/Upper Housing/Card Slot
Cover/Lower Housing
Removal procedure
1.
Release the dowel A of the Hopper.
2.
Release the dowel B of the Hopper, and remove the Hopper together with the
Compression Spring 3.43.
Dowel B
Compression Spring 3.43
Figure 4-45. Removing the Hopper
Revision A
Dowel A
Hopper
116
Confidential

Hide quick links:

Advertisement

Table of Contents
loading