Epson Stylus NX510/515/SX510W/515W/TX550W/NX415/SX410/415/TX410/419/NX215/SX210/215/TX210/213/219/ME OFFICE 510
Tighten the screws in the order given in
Insert the Holder Board Assy vertically into the CR Unit so as
not to put the Holder Board Assy on the rib of the Printhead.
Whenever the Printhead is removed/replaced, the required
A D J U S T M E N T
R E Q U I R E D
adjustments must be carried out.
Chapter 5 " ADJUSTMENT" (p.161)
DISASSEMBLY/ASSEMBLY

4.5.2 CR Scale

Figure
4-41.
Parts/Components need to be removed in advance
Document Cover/ASF Cover/Scanner Unit/Panel Unit/Upper Housing
Removal procedure
C A U T I O N
1.
2.
Disassembling the Printer Mechanism
Pay attention to the following instructions:
Do not touch the CR Scale with bare hands.
Do not damage the CR Scale.
Do not stretch Extension Spring 1.41 too much.
Release the right end of the CR Scale from the hook.
Pull out the CR Scale through the slit of the CR Encoder Sensor.
CR Scale
Slit of CR Encoder Sensor
Figure 4-43. Removing the CR Scale (1)
Revision A
Hook
CR Scale