Epson Stylus NX510/515/SX510W/515W/TX550W/NX415/SX410/415/TX410/419/NX215/SX210/215/TX210/213/219/ME OFFICE 510
NX510 series only:
A D J U S T M E N T
R E Q U I R E D
When replacing the Main Board, the MAC address need to be
set if the EEPROM data could not be read from the old Main
Board. In this case, attach the new "Label, MAC address
(Parts number: TBD)" to the position shown in
and execute
" 5.2.8 MAC Address Setting (NX510 series only) "
(p173).
Main Board Unit
Figure 4-24. Position for the MAC Address Label
Whenever the Main Board is removed/replaced, the required
adjustments must be carried out.
Chapter 5 " ADJUSTMENT" (p.161)
DISASSEMBLY/ASSEMBLY

4.4.2 Panel Unit/LCD Unit

C H E C K
P O I N T
Figure 4-24
Parts/Components need to be removed in advance: None
Removal procedure
1.
Label, MAC address
2.
C A U T I O N
3.
4.
Upper
Housing
Backside
Removing the Circuit Boards
See the following because the disassembling/reassembling
procedures of the Panel Unit/LCD Unit for SX410/SX210 series
differ from those of NX510 series.
SX410 series:
" 4.7.2 Panel Unit/LCD Unit (SX410 series) " (p148)
SX210 series:
" 4.8.2 Panel Unit/LCD Unit (SX210 series) " (p155)
Open the Scanner Unit.
Raise the LCD Unit.
Do not lift the Panel Unit too far, since the Panel FFC is connected
to it.
Lifting the front of the Panel Unit, and release the tabs of it.
Slide the Panel Unit in the direction of the arrow, and release the hooks of it
from the Upper Housing.
LCD Unit
Hook
Figure 4-25. Removing the Panel Unit and LCD Unit (1)
Revision A
Panel Unit
Tab