Nortel BayStack 450 Using Manual page 284

10/100/1000 series switch
Hide thumbs Also See for BayStack 450:
Table of Contents

Advertisement

Using the BayStack 450 10/100/1000 Series Switch
# Caution
#
#
Omitting a Forward slash (/) when the entry is continued to the next
#
line, can cause the interruption of the booting process or the
#
incorrect image file to download.
#
where needed.
#
# Important Note:
#
#
If a leading zero (0) is used in the IP address it is calculated as an
#
octal number.
#
it is calculated as a hexadecimal number. For example, if an IP address
#
with a base 10 number of 45 is written as .045 in the BOOTPTAB.TXT file,
#
the Bootp protocol assigns .037 to the client.
#
# Global entries are defined that specify the parameters used by every device.
# Note that hardware type (ht) is specified first in the global entry.
#
# The following global entry is defined for an Ethernet device. Note that this
# is where a client's subnet mask (sm) and default gateway (gw) are defined.
#
global1|/
|ht=ethernet|/
|hd=c:\opt\images|/
|sm=255.255.255.0|/
|gw=192.0.1.0|
#
# The following sample entry describes a BootP client:
bay1|ht=ethernet|ha=0060fd000000|ip=192.0.0.1|hd=c:\ezlan\images|bf=b450_100.img
# Where:
#
host name:
#
hardware type:
#
MAC address:
#
IP address:
#
home directory of boot file:
#
boot file:
G-2
If the leading character is "x" (upper or lower case),
bay1
Ethernet
00-60-FD-00-00-00
192.0.0.1
c:\ezlan\images
b450_100.img
Always include forward slashes
302401-D Rev 00

Advertisement