Chapter 8 Operation and Maintenance

8.2.2 Error Messages

This section explains the error messages for this server.
POST error messages
If an error occurs during Power On Self Test (a device check performed during the server startup)
(POST) by the server, deal with it according to the following table.
When checking/changing the settings of the BIOS Setup Utility, refer to "7.2 BIOS Setup Utility"
( p.176).
For instructions on checking peripheral connections, refer to "Start Guide".
For details on installing internal options, refer to "Chapter 6 Installing Internal Options" ( p.129).
Failure Fixed Disk
Keyboard error nn
Stuck Key nn
Keyboard controller error
Extended RAM Failed at offset: nnnn h
System RAM Failed at offset: nnnnnnnn h
Shadow RAM Failed at offset: nnnnnnnn h
Memory type mixing detected
Unsupported memory configuration detected
Correctable memory error in module n
Uncorrectable memory error in module n
Memory decreased in Size
Non Fujitsu Siemens Memory Module
detected Warranty restricted!
208
table: List of POST error messages
Message
Description
The IDE device is abnormal.
Check the "7.2.3 Standard IDE Submenu" ( p.180) settings in
the [Main] menu and the [ATA Controller Config] settings on
the "7.2.6 Peripheral Configuration Submenu" ( p.184) in the
[Advanced] menu of the BIOS Setup Utility. If the message still
appears, the baseboard must be replaced.
The keyboard is abnormal. Remove objects, if any, that are
pressing against any keys on the keyboard. ("nn" is a
hexadecimal code representing the key.) Check to see whether
the keyboard is connected properly. If the message still appears,
the keyboard must be replaced.
The keyboard controller is abnormal. Replace the keyboard or
mouse. If the message still appears, the baseboard must be
replaced. Contact an office listed in the "Contact Information"
of the "Start Guide".
The memory is abnormal. Stop the server once, then restart it. If
the message still appears, check the error log and replace the
faulty memory. If the message still appears after replacing the
faulty memory, the baseboard must be replaced. Contact an
office listed in the "Contact Information" of the "Start Guide".
The installation configuration of the memory is wrong. Verify
that the same type of memory is installed to the slots of the same
memory pair. If the memory is properly installed, it needs to be
replaced.
The memory is abnormal. Replace the memory module that
corresponds to "module n" (where n is the slot number). If the
message still appears after replacing the faulty memory, the
baseboard must be replaced. Contact an office listed in the
"Contact Information" of the "Start Guide".
The memory is abnormal. Power off the server and turn it back
on. If the message still appears, check the error log and replace
the faulty memory. If the message still appears after replacing
the faulty memory, the baseboard must be replaced. Contact an
office listed in the "Contact Information" of the "Start Guide".