Rx200 S4 - Fujitsu PRIMERGY RX200 S4 User Manual

Hide thumbs Also See for PRIMERGY RX200 S4:
Table of Contents

Advertisement

Chapter 1 Overview

1.1 RX200 S4

This server contains an [SAS model] which is where the SAS Ctrl is standardly
installed, and an [SATA model] which configures an array by using an onboard SATA
controller.
This server has the following features.
High reliability
Advanced memory protection function
The server supports the Single Device Data Correction (SDDC) function using PC2-5300F (DDR2-667)
compliant memory (Fully Buffered DIMM). Also, memory mirroring function and memory sparing
function are supported to enable data recovery in the event of a memory error.
Disk array system configuration
Both SAS models and SATA models can configure an array.
Also, a higher reliability array can be configured using the optional SAS RAID Ctrl (PG-248B/PG-
248C) for SAS model.
A failed hard disk unit can be replaced or repaired without turning off the server and peripheral devices
depending on the array configuration (a hot plug is supported in configurations other than RAID0).
Redundant function
The hard disk units, power supply units, and system fans support the redundant function.
A failed hard disk unit can be replaced or repaired without turning off the server and peripheral devices
when the array is configured (a hot plug is supported in configurations other than RAID0).
Adding an optional power supply unit enables the redundant function.
Hardware and software designed for data security
The locks on the rack and security (password) setting in the BIOS Setup Utility protect hardware and
data assets in the server against theft, ensuring data security with high reliability.
Proactive fan function
When a fan fails or the ambient temperature rises, the system fan speed is increased automatically to
avoid increase in temperature in the server, ensuring stable server operation.
Remote management control function
This server has a function of the onboard remote service board. By using the Remote Management
Control function, you can use the Web interface to power on/off or reset the server (remote control
function) and to monitor the server.
For details, refer to "Appendix D Remote Management Controller" ( P. 257).