Chapter 6 Installing Internal Options
4
Install or remove memory modules.
When installing memory modules
Keep the levers on both sides of the slot where the memory module is to be installed open, and
insert the memory module vertically in the memory slot while lining up the notch.
When the memory module is properly installed, the levers on both sides of the slot are pulled
back. At this time, confirm that the memory module is secured. If the levers are not pulled back
completely, make sure the levers are pushed inwards.
Lever
When removing memory modules
Pull the levers on both sides of the slot outwards and remove the memory module.
Lever
5
Attach the fan duct.
6
Attach the top cover and push the server back into the rack.
"6.2 Attaching/Removing the Top Cover" (p.132)
7
Initialize the Extended System Configuration Data (ESCD).
Set [Reset Configuration Data] to [Yes] in the [Advanced] menu of the BIOS Setup Utility.
"7.2.5 Advanced Menu" (p.183)
8
Save the BIOS configuration data.
"4.3 Storing the System Configuration Information" (p.82)
146
Align notch
• If the memory module has not been correctly inserted, it may cause a fire.
Insert the memory module with attention to its direction.
• If a memory module is installed and you pull the hook strongly outwards, the
memory module pops up. Doing so may cause a device failure.