6.14.2 MAINTENANCE

If the vehicle remains unused for more than fifteen
days, the battery must be recharged to prevent
sulphation. Recharge the battery using a normal
charge, see 2.4.2 (RECHARGING THE BATTERY).
Smear a thin film of neutral grease or Vaseline on the
terminals.

6.14.3 CHECKING

Should you run into any difficulty with the battery
maintaining a charge, first check the recharging circuit to
make sure it is functioning correctly; see 6.3 (CHECKING
THE RECHARGING SYSTEM).
Also make sure that:
There are no signs of damage (external case cracked)
and no electrolyte leak.
The cables are firmly connected to the terminals.
Apply a normal charge for at least 10 hours.
WARNING
After recharging, check the open-circuit voltage
again: if it is below 12V, the battery must be replaced.

6.14.4 RETURN UNDER WARRANTY

The warranty is void if the battery shows:
Damage (container dented, poles bent, etc.).
Widespread sulphation (incorrect activation and/or
misuse of the battery).