Checking The Recharging System; Checking The Recharging Voltage; Checking The Open-Circuit; Alternator Operation - APRILIA RST mille Futura 2001 Service Manual

Hide thumbs Also See for RST mille Futura 2001:
Table of Contents

Advertisement

ELECTRICAL SYSTEM

6.3 CHECKING THE RECHARGING SYSTEM

6.3.1 CHECKING THE RECHARGING VOLTAGE

Check the battery voltage, see 2.4.2 (RECHARGING
THE BATTERY).
Start the engine and rev it to 4000 rpm.
Set the light switch to "
Set the light dimmer to "
Use a tester to measure the DC voltage between the
positive (+) and negative (–) terminals of the battery.
If the tester indicates voltages below 13 V or above 15 V:
Check the open-circuit operation and continuity of the
alternator,
see 6.3.2
CIRCUIT
ALTERNATOR
(CHECKING ALTERNATOR CONTINUITY) and the
voltage
regulator,
see 6.3.5
VOLTAGE REGULATOR).
Wiring diagram legend
NOTE
For the positions of the components, see 6.1
(LOCATIONS OF ELECTRICAL COMPONENTS).
1) Battery
2) Main fuses (30 A)
3) Alternator
4) Voltage regulator
5) Ignition switch (
-
Standard charge voltage: 13 - 15 V (DC) at 4000 rpm.
6.3.2 CHECKING

ALTERNATOR OPERATION

Remove the left lower fairing, see 7.1.33 (REMOVING
THE LOWER FAIRING).
Disconnect the three-way connector (1) (brown)
voltage regulator cables.
WARNING
When
reassembling,
connector (1) is properly connected.
Start the engine and rev it to 4000 rpm.
Use a tester to measure the voltage (AC) from the
three internal male terminals [yellow cables (G)] in
rotation.
If the output voltage is less than 60 V, the alternator is
faulty and must be replaced.
Standard open-circuit voltage:
greater than 60 V (AC) at 4000 rpm.
6
- 6 -
00
" and the light dimmer to "
".
(CHECKING
THE
OPEN-
OPERATION),
6.3.4
(CHECKING
-
-
)
THE
OPEN-CIRCUIT
make
sure
the
electrical
" .
THE
3
RST mille
4
1
1
Release 00/2002 - 03
USA
5
2
1

Advertisement

Table of Contents
loading

Table of Contents