1. If the NON LED on the diagnostic LED panel is lit, turn off the server and
2. Remove the power supply:
CAUTION:
The following label indicates a hot surface nearby.
3. If you are replacing the power supply with another one, go to step 4.
4. If you are replacing the power supply:
5. If you have other options to install or remove, do so now; otherwise, go to

Removing the only power supply

To remove the only power supply:
1. Turn off the server and peripheral devices.
2. Remove the power supply:
68
Hardware Maintenance Manual: xSeries 230 Models 6RY, 61Y
peripheral devices; otherwise, go to the next step.
a. Unplug the power cord connector from the power supply.
Attention:
Be careful when you remove the hot-swap power supply; the
power supply might be too hot to handle comfortably.
b. Remove the defective power supply by placing the handle on the power
supply in the open position (perpendicular to the power supply) and
pulling the power supply from the bay.
Otherwise, continue with step 3a.
a. Install a power-supply filler panel.
Note: During normal operation, each power-supply bay must have either a
power supply or filler panel installed for proper cooling.
b. Open the cable-restraint bracket and remove the power cord from the
cable-restraint bracket. Close the cable-restraint bracket.
c. Unplug the power cord from the electrical outlet.
d. Continue with step 5.
a. Place the handle on the replacement power supply in the open position;
then, slide the power supply into the chassis.
b. Gently close the handle on the power supply to seat the power supply in
the bay.
c. Plug the power cord for the power supply into the power cord connector.
d. Verify that the AC Power light and DC Power light are lit, indicating that
the power supply is operating correctly.
"Installing the cover" on page 70.
a. Unplug the power cord from the power supply.
Attention:
Be careful when you remove the power supply; the power
supply might be too hot to handle comfortably.