IBM xSeries 230 6RY Hardware Maintenance Manual page 146

Table of Contents

Advertisement

Error Code/Symptom
1962 (Drive does not contain a valid boot
sector)
2400 (Video controller test failure)
2462 (Video memory configuration error)
5962 (IDE CD-ROM configuration error)
8603 (Pointing Device Error)
00019501 (Processor 1 is not functioning -
check VRM and processor LEDs)
00019502 (Processor 2 is not functioning -
check VRM and processor LEDs)
00019701 (Processor 1 failed BIST)
00019702 (Processor 2 failed BIST)
00180100 (No room for PCI option ROM)
00180200 (No more I/O space available for
PCI adapter)
00180300 (No more memory (above 1MB for
PCI adapter)
00180400 (No more memory (below 1MB for
PCI adapter)
138
Hardware Maintenance Manual: xSeries 230 Models 6RY, 61Y
FRU/Action
1. Verify a bootable operating system is installed.
2. Run Diagnostics
3. Hard Disk Drive
4. SCSI Backplane
5. Cable
6. System Board
1. Video Adapter (if installed)
2. System Board
1. Video Adapter (if installed)
2. System Board
1. Run Configuration/Setup
2. CD-ROM Drive
3. CD-ROM Power Cable
4. IDE Cable
5. System Board
6. Battery
1. Pointing Device
2. System Board
1. VRM 1, VRM 2
2. Processor 1
3. System Board
1. VRM 2
2. Processor 2
3. System Board
1. Processor 1
2. System Board
1. Processor 2
2. System Board
1. Run Configuration/Setup
2. Failing Adapter
3. System Board
1. Run Configuration/Setup
2. Failing Adapter
3. System Board
1. Run Configuration/Setup
2. Failing Adapter
3. System Board
1. Run Configuration/Setup
2. Move the failing adapter to slot 1 or 2
3. Failing Adapter
4. System Board