IBM 8841 - eServer xSeries 236 Installation Manual

Installation guide
Hide thumbs Also See for 8841 - eServer xSeries 236:
Table of Contents

Advertisement

Quick Links

xSeries 236
Type 8841

Installation Guide

Welcome.
Thank you for buying an
IBM xSeries server.
is based on the X-Architecture
technology, and it features
superior performance, availability,
and scalability.
Installation Guide
This server
contains information for setting
up and configuring your server.
For detailed information about
your server, view the publications
on the
Documentation CD.
You can also find the most
current information about your
server at
http://www.ibm.com/pc/support.
Your server
Start the server.
No
Did the server
start correctly?
Yes
Turn off the server
and install options.
Cable the server and options;
then, restart the server.
No
Did the server
start correctly?
Yes
Use the IBM
ServerGuide program
to set up and
configure hardware.
Was the
server setup
completed?
Yes
Use
ServerGuide to
install the operating
system?
Yes
Install applications,
such as IBM systems
management software
and IBM ServeRAID
programs
The server is ready to use.
Go to
http://www.ibm.com/pc/register/
to register the server.
Go to the Server Support
flow chart on the reverse
side of this page.
Go to the Server Support
flow chart on the reverse
side of this page.
No
No
Go to the Web for instructions:
http://www.ibm.com/support/

Advertisement

Table of Contents
loading

Summary of Contents for IBM 8841 - eServer xSeries 236

  • Page 1: Installation Guide

    ServerGuide to Go to the Web for instructions: http://www.ibm.com/pc/support. install the operating http://www.ibm.com/support/ system? Install applications, such as IBM systems management software and IBM ServeRAID programs The server is ready to use. Go to http://www.ibm.com/pc/register/ to register the server.
  • Page 2: Server Support

    Check all cables for loose connections and verify that all optional devices you installed are on the ServerProven list at http://www.ibm.com/servers/eserver/ serverproven/compat/us/. View information about IBM Support Line at http://www.ibm.com/services/sl/products/ or view support telephone numbers at Is the problem http://www.ibm.com/planetwide/.
  • Page 3 IBM xSeries 236 Type 8841 Installation Guide...
  • Page 4 Note: Before using this information and the product it supports, read the general information in Appendix B, “IBM Statement of Limited Warranty Z125-4753-08 04/2004,” on page 57, and Appendix C, “Notices,” on page 75. Third Edition (September 2005) © Copyright International Business Machines Corporation 2005. All rights reserved.
  • Page 5: Table Of Contents

    Chapter 1. Introduction ..... . 1 The IBM xSeries Documentation CD ....2 Hardware and software requirements .
  • Page 6 Using the PXE boot agent utility program ....40 Chapter 5. Updating IBM Director ....41 Chapter 6.
  • Page 7 Japanese Voluntary Control Council for Interference (VCCI) statement . . . 80 Index ......81 Contents...
  • Page 8 IBM xSeries 236 Type 8841: Installation Guide...
  • Page 9: Safety

    Vor der Installation dieses Produkts die Sicherheitshinweise lesen. Prima di installare questo prodotto, leggere le Informazioni sulla Sicurezza. Les sikkerhetsinformasjonen (Safety Information) før du installerer dette produktet. Antes de instalar este produto, leia as Informações sobre Segurança. © Copyright IBM Corp. 2005...
  • Page 10 All caution and danger statements in this documentation begin with a number. This number is used to cross reference an English caution or danger statement with translated versions of the caution or danger statement in the IBM Safety Information book.
  • Page 11 Statement 1: DANGER Electrical current from power, telephone, and communication cables is hazardous. To avoid a shock hazard: v Do not connect or disconnect any cables or perform installation, maintenance, or reconfiguration of this product during an electrical storm. v Connect all power cords to a properly wired and grounded electrical outlet.
  • Page 12 Statement 2: CAUTION: When replacing the lithium battery, use only IBM Part Number 33F8354 or an equivalent type battery recommended by the manufacturer. If your system has a module containing a lithium battery, replace it only with the same module type made by the same manufacturer.
  • Page 13 Statement 4: ≥ 18 kg (39.7 lb) ≥ 32 kg (70.5 lb) ≥ 55 kg (121.2 lb) CAUTION: Use safe practices when lifting. Statement 5: CAUTION: The power control button on the device and the power switch on the power supply do not turn off the electrical current supplied to the device.
  • Page 14 Hazardous voltage, current, and energy levels are present inside any component that has this label attached. There are no serviceable parts inside these components. If you suspect a problem with one of these parts, contact a service technician. IBM xSeries 236 Type 8841: Installation Guide...
  • Page 15: Chapter 1. Introduction

    These updates are available from the IBM Web site. To check for updated documentation and technical updates, complete the following steps: Note: Changes are made periodically to the IBM Web site.
  • Page 16: The Ibm Xseries Documentation Cd

    The IBM xSeries Documentation CD The IBM xSeries Documentation CD contains documentation for the server in Portable Document Format (PDF) and includes the IBM Documentation Browser to help you find information quickly. IBM xSeries 236 Type 8841: Installation Guide...
  • Page 17: Hardware And Software Requirements

    Hardware and software requirements The IBM xSeries Documentation CD requires the following minimum hardware and software: ® ® ® v Microsoft Windows NT 4.0 (with Service Pack 3 or later),Windows 2000, or Red Hat Linux. Note: Microsoft NT is not supported on the xSeries 236.
  • Page 18: Notices And Statements Used In This Document

    Notices and statements used in this document The caution and danger statements that appear in this document are also in the multilingual Safety Information document, which is on the IBM xSeries Documentation CD. Each statement is numbered for reference to the corresponding statement in the Safety Information document.
  • Page 19: Features And Specifications

    Electrical input: v Type: 400 MHz, registered, ECC, interconnect) v Sine-wave input (50-60 Hz) required PC2-3200 double data rate II, – Support for IBM Remote Supervisor v Input voltage range automatically selected Adapter II SlimLine SDRAM v Input voltage low range:...
  • Page 20: Major Components Of The Xseries 236 Type 8841 Server

    Rear fans 5 and 6 (optional) Diskette drive Center fans CD-Rom drive 3 and 4 Operator information Air-baffle panel Bezel Hard disk Front fans drive 1 and 2 Adapter-support Server door bracket Left-side cover IBM xSeries 236 Type 8841: Installation Guide...
  • Page 21: Chapter 2. Installing Options

    Chapter 2. Installing options This chapter provides basic instructions for installing hardware options in the server. These instructions are intended for users who are experienced with setting up IBM server hardware. If you need more detailed instructions, see the Option Installation Guide on the IBM xSeries Documentation CD.
  • Page 22: Working Inside The Server With The Power On

    Do not place the device on the server cover or on a metal surface. v Take additional care when handling devices during cold weather. Heating reduces indoor humidity and increases static electricity. IBM xSeries 236 Type 8841: Installation Guide...
  • Page 23: Removing The Server Door

    Removing the server door The following illustration shows how to remove the door from the server. Flange Server door Complete the following steps to remove the server door: 1. Read the safety information beginning on page vii, and “Installation guidelines” on page 7.
  • Page 24: Removing The Server Side Cover And Bezel

    For proper cooling and airflow, replace the cover before turning on the server. Operating the server for extended periods of time (more than 30 minutes) with the cover removed might damage server components. IBM xSeries 236 Type 8841: Installation Guide...
  • Page 25: Removing The Bezel

    PC3200 SDRAM Registered DIMM specification. For a list of supported options for the server, go to http://www.ibm.com/servers/eserver/serverproven/compat/us. v When you install additional DIMMs, be sure to install them in pairs. The DIMMs in each pair must be the same size, and type. You can mix compatible DIMMs from various manufacturers.
  • Page 26: Installing A Hot-Swap Hard Disk Drive

    When you restart the server after adding or removing a DIMM, the server displays a message that the memory configuration has changed. v See the Option Installation Guide on the IBM xSeries Documentation CD for more information about memory mirroring and the on-line spare feature.
  • Page 27 RAID capabilities or an optional ServeRAID controller, you must configure the disk arrays before installing the operating system. See the ServeRAID documentation on the IBM ServeRAID Support CD for additional information about RAID operation and complete instructions for using ServeRAID Manager.
  • Page 28: Installing An Additional Microprocessor

    For a list of supported options for the server, go to http://www.ibm.com/servers/eserver/serverproven/compat/us. v See the Option Installation Guide on the IBM xSeries Documentation CD for details on how to install a microprocessor. v The server supports Intel Xeon 2.8 GHz or higher microprocessors in each socket.
  • Page 29 Heatsink 2 Microprocessor 2 Microprocessor 2 VRM Microprocessor release lever Microprocessor baffle 5. Install the VRM. 6. Install the microprocessor: a. Touch the static-protective package containing the new microprocessor to any unpainted metal surface on the server; then, remove the microprocessor from the package.
  • Page 30: Installing An Adapter

    Locate the documentation that comes with the adapter and follow those instructions in addition to the instructions in this section. If you must change the switch or jumper settings on the adapter, follow the instructions that come with the adapter. IBM xSeries 236 Type 8841: Installation Guide...
  • Page 31 Note: To change the boot precedence for PCI and PCI-X devices, start the Configuration/Setup Utility program and select Start Options from the main menu. See the User’s Guide on the IBM xSeries Documentation CD for details about using the Configuration/Setup Utility program.
  • Page 32 7. Connect any needed cables to the adapter. 8. If you have other options to install or remove, do so now. 9. Replace the cover. Go to “Completing the installation” on page 22. IBM xSeries 236 Type 8841: Installation Guide...
  • Page 33: Installing A Hot-Plug Adapter (Slot 6)

    Installing a hot-plug adapter (slot 6) You do not have to turn off the server to install a hot-plug adapter in slot 6. However, you must turn off the server when performing any steps that involve installing or removing cables. The following illustration shows how to install a PCI or PCI-X hot-plug adapter.
  • Page 34: Installing An Ibm Remote Supervisor Adapter Ii Slimline

    10. Replace the cover. Go to “Completing the installation” on page 22. Installing an IBM Remote Supervisor Adapter II SlimLine The optional IBM Remote Supervisor Adapter II SlimLine must be installed in its dedicated connector on the system board. See the illustration on page 22 for the location of the connector on the system board.
  • Page 35 Connector Standoffs Standoffs Interposer card Mounting hole Remote Supervisor Adapter II SlimLine Standoffs Mounting hole a. Insert the standoffs that come with the option into the mounting holes in the Remote Supervisor Adapter II SlimLine. b. Align the mounting holes in the Interposer card with the standoffs; then, align the connector on the card with the connector on the Remote Supervisor Adapter II SlimLine.
  • Page 36: Installing The Serveraid-7K Adapter

    2. Connect the cables and power cords. See “Connecting the cables” for more information. Connecting the cables Notes: 1. Make sure you turn off the server before connecting any cables to or disconnecting any cables from the server or hot-plug adapter. IBM xSeries 236 Type 8841: Installation Guide...
  • Page 37 2. For additional cabling instructions, see the User’s Guide on the IBM xSeries Documentation CD and the documentation that comes with the options. It might be easier for you to route any cables before you install certain options. 3. Cable identifiers are printed on the cables that come with the server and options.
  • Page 38: Updating The Server Configuration

    The Configuration/Setup Utility program starts automatically so that you can save the new configuration settings. For more information, see the section about configuring the server in the User’s Guide on the IBM xSeries Documentation Some options have device drivers that you must install. See the documentation that comes with each option for information about installing device drivers.
  • Page 39: Chapter 3. Server Controls, Leds, And Power

    LEDs on the operator information panel. System System Hard Disk Drive Information LED Error LED Power-on Activity LED Ethernet System Locator LED Transmit/Receive LEDs The following LEDs are on the operator information panel: © Copyright IBM Corp. 2005...
  • Page 40 Documentation CD for additional information. v System locator LED: Use this LED to visually locate the server among other servers. You can use IBM Director to light this LED remotely. v Ethernet transmit/receive activity LED (Tx/Rx 1 or Tx/Rx 2): When these two green LEDs are lit, they indicate that there is activity between the server and the network.
  • Page 41: Rear View

    CD-eject button: Press this button to release a CD from the CD-ROM drive. Rear view The following illustration shows the connectors and LEDs on the rear of the server. Keyboard connector Mouse connector Parallel connector Ethernet link LED Serial 1 connector Remote Supervisor Adapter II SlimLine Ethernet...
  • Page 42 LEDs, see the Hardware Maintenance Manual and Troubleshooting Guide on the IBM xSeries Documentation CD. AC power LED: This green LED provides status information about the power supply. During typical operation, both the ac and dc power LEDs are lit. For any other combination of LEDs, see the Hardware Maintenance Manual and Troubleshooting Guide on the IBM xSeries Documentation CD.
  • Page 43: Server Power Features

    Server power features When the server is connected to an ac power source but is not turned on, the operating system does not run, and all core logic except for the service processor is shut down; however, the server can respond to requests from the service processor (also called the baseboard management controller), such as a remote request to turn on the server.
  • Page 44: Turning Off The Server

    The integrated system management processor can turn off the server as an automatic response to a critical system failure. v You can turn off the server through a request from the service processor. IBM xSeries 236 Type 8841: Installation Guide...
  • Page 45: Chapter 4. Configuring The Server

    Chapter 4. Configuring the server The ServerGuide Setup and Installation CD provides software setup tools and installation tools that are specifically designed for your IBM server. Use this CD during the initial installation of the server to configure basic hardware features and to simplify the operating-system installation.
  • Page 46: Using The Baseboard Management Controller Utility Programs

    LAN configuration, and LAN alert settings. Go to http://www.ibm.com/support/ to download the program; then, copy the files bmc.exe and Init.ini to a setup utility diskette. Complete the following steps to start the baseboard management controller setup utility program: 1.
  • Page 47: Using The Baseboard Management Controller Firmware Update Utility Program

    Go to http://www.ibm.com/support/ to download the program; then, copy the file Flash.exe to a firmware update diskette. To update the firmware, use one of the following procedures:...
  • Page 48: Using The Baseboard Management Controller Management Utility Program

    SCSI RAID configuration utilities, device drivers, and information are available on the ServeRAID-7e (Adaptec HostRAID) Support CD. If this CD did not come with your server, you can download the IBM ServeRAID-7e (Adaptec HostRAID) Support CD from the IBM Web site at http://www.ibm.com/pc/support/.
  • Page 49: Using The Scsi Hostraid Feature To Perform A Raid Level-1 Configuration

    See the documentation on the ServeRAID-7e (Adaptec HostRAID) Support CD for additional information about how to use the SCSI HostRAID feature. Configuring the controller Complete the following steps to use the SCSI HostRAID feature to configure a RAID level-0 array: Note: You must have at least two hard disk drives installed in the server to configure a RAID level-0 array.
  • Page 50: Using The Scsi Hostraid Feature To Perform A Raid Level-10 Configuration

    From the list of available arrays, select an array and press Enter. Press Esc to exit the utility. Using ServeRAID Manager You can use the ServeRAID Manager program, which is on the IBM ServeRAID Support CD, to: v Configure a redundant array of independent disks (RAID) array...
  • Page 51: Configuring The Controller

    1. You cannot use the ServerGuide Setup and Installation CD to configure the optional controllers. 2. To update the firmware and BIOS code for an optional ServeRAID controller, you must use the IBM ServeRAID Support CD that comes with the ServeRAID option. Configuring the controller You can use the Configuration wizard to configure your controller.
  • Page 52: Using Custom Configuration

    Complete the following steps to use Custom configuration: 1. In the ServeRAID Manager tree, click the controller. 2. Click Custom configuration. 3. Click Next. The “Create arrays” window opens. IBM xSeries 236 Type 8841: Installation Guide...
  • Page 53 Figure 2. “Create arrays” window 4. From the list of ready drives, select the two drives you want to move to the array. 5. Click (Add selected drives) to add the drives to the array. 6. Complete the following steps if you want to configure a hot-spare drive: a.
  • Page 54: Using The Pxe Boot Agent Utility Program

    3. Use the arrow keys and press Enter to select a choice from the menu. 4. Follow the instructions on the screen to change the settings of the selected items; then, press Enter. IBM xSeries 236 Type 8841: Installation Guide...
  • Page 55: Chapter 5. Updating Ibm Director

    Chapter 5. Updating IBM Director If you plan to use IBM Director to manage the server, you must check for the latest applicable IBM Director updates and interim fixes. Complete the following steps to install the IBM Director updates and any other applicable updates and interim fixes: 1.
  • Page 56 IBM xSeries 236 Type 8841: Installation Guide...
  • Page 57: Chapter 6. Solving Problems

    Note: See the Hardware Maintenance Manual and Troubleshooting Guide on the IBM xSeries Documentation CD for more information about the POST beep codes. One beep POST was completed successfully without finding any errors.
  • Page 58: Post Error Messages

    The following table provides an abbreviated list of the error messages that might appear during POST. See the Hardware Maintenance Manual and Troubleshooting Guide on the IBM xSeries Documentation CD for more information about the POST error messages. Table 3. Abbreviated list of POST error messages...
  • Page 59: Serverguide Problems

    ServerGuide problems The following table lists problem symptoms and suggested solutions. Table 4. ServerGuide Setup and Installation CD Symptom Suggested action The ServerGuide Setup and v Make sure that the server supports the ServerGuide program and has a Installation CD will not start. startable (bootable) CD-ROM (or DVD-ROM) drive.
  • Page 60: Troubleshooting Charts

    Troubleshooting charts The following tables list problem symptoms and suggested solutions. See the Hardware Maintenance Manual and Troubleshooting Guide on the IBM xSeries Documentation CD for more detailed troubleshooting charts. If you cannot find the problem in these charts, run the diagnostic programs. If you have run the diagnostic programs or if running the tests does not reveal the problem, call for service.
  • Page 61: General Problems

    General problems Symptom Suggested action A cover lock is broken, an LED Call for service. is not working, or a similar problem has occurred. Hard disk drive problems Symptom Suggested action Not all drives are recognized by 1. Remove the first drive that is not recognized and try the hard disk drive the hard disk drive diagnostic diagnostic test again.
  • Page 62: Memory Problems

    If the problem remains, call for service. Monitor problems Some IBM monitors have their own self-tests. If you suspect a problem with your monitor, see the information that comes with the monitor for instructions for testing and adjusting the monitor. If you cannot diagnose the problem, call for service.
  • Page 63: Option Problems

    1. To prevent diskette drive read/write errors, make sure that the distance between the monitor and diskette drives is at least 75 mm (3 in.). 2. Non-IBM monitor cables might cause unpredictable problems. 3. An enhanced monitor cable with additional shielding is available for the 9521 and 9527 monitors.
  • Page 64: Power Problems

    If you received any error messages when using the software, see the information that comes with the software for a description of the messages and suggested solutions to the problem. If the problem remains, contact your place of purchase of the software. IBM xSeries 236 Type 8841: Installation Guide...
  • Page 65: Universal Serial Bus Device Problems

    For more information about light path diagnostics, see the Hardware Maintenance Manual and Troubleshooting Guide on the IBM xSeries Documentation CD. Diagnosing problems using the light path diagnostics LEDs in three locations on the server are available to help you diagnose problems that might occur during installation.
  • Page 66 Note the lit LEDs and follow the instructions on the system service label. 3. LEDs on the system board - To identify the component that is causing the error, note the lit LED next to the component. IBM xSeries 236 Type 8841: Installation Guide...
  • Page 67: Light Path Diagnostics Leds

    If a lit LED on the system board indicates a problem with a microprocessor, make sure that the microprocessor is installed correctly. See the Option Installation Guide on the IBM xSeries Documentation CD for information about installing a microprocessor. If the problem remains, call for service.
  • Page 68 A machine check error has Check the error log to diagnose the condition. occurred. Note: The amber CONFIG LED is lit only when the Diagnostics Panel LED test is performed by Enhanced Diagnostics. IBM xSeries 236 Type 8841: Installation Guide...
  • Page 69: Appendix A. Getting Help And Technical Assistance

    If you need help, service, or technical assistance or just want more information about IBM products, you will find a wide variety of sources available from IBM to assist you. This appendix contains information about where to go for additional...
  • Page 70: Getting Help And Information From The World Wide Web

    Getting help and information from the World Wide Web On the World Wide Web, the IBM Web site has up-to-date information about IBM Eserver and IntelliStation systems, optional devices, services, and support. The ® address for IBM xSeries and BladeCenter information is http://www.ibm.com/eserver/xseries/.
  • Page 71: Appendix B. Ibm Statement Of Limited Warranty Z125-4753-08 04/2004

    Country-unique Terms, and Part 3 - Warranty Information. The terms of Part 2 replace or modify those of Part 1. The warranties provided by IBM in this Statement of Limited Warranty apply only to Machines you purchase for your use, and not for resale.
  • Page 72 If the Machine does not function as warranted during the warranty period, contact IBM or your reseller to obtain warranty service. If you do not register the Machine with IBM, you may be required to present proof of purchase as evidence of your entitlement to warranty service.
  • Page 73 Personal Data. Limitation of Liability IBM is responsible for loss of, or damage to, your Machine only while it is 1) in IBM’s possession or 2) in transit in those cases where IBM is responsible for the transportation charges.
  • Page 74: Part 2 - Country-Unique Terms

    TO YOU. Governing Law Both you and IBM consent to the application of the laws of the country in which you acquired the Machine to govern, interpret, and enforce all of your and IBM’s rights, duties, and obligations arising from, or relating in any manner to, the subject matter of this Statement of Limited Warranty, without regard to conflict of law principles.
  • Page 75 Limitation of Liability: The following is added at the end of this section: In accordance with Article 1328 of the Peruvian Civil Code the limitations and exclusions specified in this section will not apply to damages caused by IBM’s willful misconduct (“dolo”) or gross negligence (“culpa inexcusable”).
  • Page 76 Limitation of Liability: The following is added to this section: Where IBM is in breach of a condition or warranty implied by the Trade Practices Act 1974 or other similar legislation, IBM’s liability is limited to the repair or replacement of the goods or the supply of equivalent goods.
  • Page 77 2. as to any other actual damage arising in any situation involving nonperformance by IBM pursuant to, or in any way related to the subject of this Statement of Limited Warranty, the charge paid by you for the individual Machine that is the subject of the claim.
  • Page 78 Consumer Guarantees Act 1993 or other legislation which cannot be excluded or limited. The Consumer Guarantees Act 1993 will not apply in respect of any goods which IBM provides, if you require the goods for the purposes of a business as defined in that Act.
  • Page 79 Machine in any of those countries from either (1) an IBM reseller approved to perform warranty service or (2) from IBM, provided the Machine has been announced and made available by IBM in the country in which you wish to obtain service.
  • Page 80 Statement of Limited Warranty will be brought before, and settled exclusively by, the competent court of a) Athens for Greece, b) Tel Aviv-Jaffa for Israel, c) Milan for Italy, d) Lisbon for Portugal, and e) IBM xSeries 236 Type 8841: Installation Guide...
  • Page 81 598 (2) of the Austrian Code of Civil Procedure, the parties expressly waive the application of paragraph 595 (1) figure 7 of the Code. IBM may, however, institute proceedings in a competent court in the country of installation.
  • Page 82 Except as otherwise provided by mandatory law: 1. IBM’s liability for any damages and losses that may arise as a consequence of the fulfillment of its obligations under or in connection with this Statement of Limited Warranty or due to any other cause related to this Statement of Limited...
  • Page 83 The limitation period for consumers in action for breach of warranty is the statutory period as a minimum. In case IBM or your reseller is unable to repair an IBM Machine, you can alternatively ask for a partial refund as far as justified by the reduced value of the unrepaired Machine or ask for a cancellation of the respective agreement for such Machine and get your money refunded.
  • Page 84 For the purposes of this section, a “Default” means any act, statement, omission, or negligence on the part of IBM in connection with, or in relation to, the subject matter of this Statement of Limited Warranty in respect of which IBM is legally liable to...
  • Page 85 For the purposes of this section, a “Default” means any act, statement, omission, or negligence on the part of IBM in connection with, or in relation to, the subject matter of this Statement of Limited Warranty in respect of which IBM is legally liable to you, whether in contract or tort.
  • Page 86: Part 3 - Warranty Information

    Note: “Region” means either Hong Kong or Macau Special Administrative Region of China. A warranty period of 3 years on parts and 1 year on labor means that IBM provides warranty service without charge for: 1. parts and labor during the first year of the warranty period; and 2.
  • Page 87 IBM at any time on your request. Installation of Tier 1 CRUs is your responsibility. If IBM installs a Tier 1 CRU at your request, you will be charged for the installation. You may install a Tier 2 CRU yourself or request IBM to install it, at no additional charge, under the type of warranty service designated for your Machine.
  • Page 88 When a 5, 6 or 7 type of warranty service is listed, IBM will determine which type of warranty service is appropriate for the repair. * This type of service is called ThinkPad EasyServ or EasyServ in some countries. The IBM Machine Warranty World Wide Web site at http://www.ibm.com/servers/support/machine_warranties/ provides a worldwide...
  • Page 89: Appendix C. Notices

    Web sites. The materials at those Web sites are not part of the materials for this IBM product, and use of those Web sites is at your own risk. IBM may use or distribute any of the information you supply in any way it believes appropriate without incurring any obligation to you.
  • Page 90: Trademarks

    When referring to processor storage, real and virtual storage, or channel volume, KB stands for approximately 1000 bytes, MB stands for approximately 1 000 000 bytes, and GB stands for approximately 1 000 000 000 bytes. IBM xSeries 236 Type 8841: Installation Guide...
  • Page 91: Product Recycling And Disposal

    IBM makes no representations or warranties with respect to non-IBM products. Support (if any) for the non-IBM products is provided by the third party, not IBM. Some software may differ from its retail version (if available), and may not include user manuals or all program functionality.
  • Page 92: Battery Return Program

    In the United States, IBM has established a return process for reuse, recycling, or proper disposal of used IBM sealed lead acid, nickel cadmium, nickel metal hydride, and battery packs from IBM equipment. For information on proper disposal of these batteries, contact IBM at 1-800-426-4333.
  • Page 93: Electronic Emission Notices

    Properly shielded and grounded cables and connectors must be used in order to meet FCC emission limits. IBM is not responsible for any radio or television interference caused by using other than recommended cables and connectors or by unauthorized changes or modifications to this equipment.
  • Page 94: Taiwanese Class A Warning Statement

    Taiwanese Class A warning statement Chinese Class A warning statement Japanese Voluntary Control Council for Interference (VCCI) statement IBM xSeries 236 Type 8841: Installation Guide...
  • Page 95 DC power LED 27 hot-plug adapter 20, 22 diskette drive VRM 15 problems 46 integrated diskette drive activity LED 26 baseboard management controller utility diskette-eject button 26 programs 32 documentation CD 2 intermittent problems 47 door removing 9 © Copyright IBM Corp. 2005...
  • Page 96 43 PCI expansion slots 5 specifications 5 pointing device problems 47 starting POST error messages 44 the server 29 power LED 26 statements and notices 4 power problems 50 power supply specifications 5 IBM xSeries 236 Type 8841: Installation Guide...
  • Page 97 trademarks 76 troubleshooting chart 46 turning off the server 30 turning on the server 29 United States electronic emission Class A notice 79 United States FCC Class A notice 79 Universal Serial Bus (USB) problems 51 updating the firmware code 32 USB 1 connector 27 USB 2 connector 27 USB connector 26...
  • Page 98 IBM xSeries 236 Type 8841: Installation Guide...
  • Page 100 Part Number: 31R1188 Printed in USA (1P) P/N: 31R1188...

This manual is also suitable for:

Xseries 236 8841

Table of Contents