Advanced System Management Ports - IBM xSeries 230 6RY Hardware Maintenance Manual

Table of Contents

Advertisement

3. When the driver is loaded, bind it to a protocol stack.
The failover function is now enabled. If a failover occurs:
v The operating system console generates a message.
v The custom counters for the device driver contain variables that define the state
Note: If the primary adapter was hot-replaced while the Ethernet traffic was being
Ethernet port connector
The following table shows the pin-number assignments for the RJ-45 connector.
These assignments apply to both 10BASE-T and 100BASE-TX devices.
Table 18. Ethernet RJ-45 connector pin-number assignments.
Pin
Signal
1
Transmit data+
2
Transmit data-
3
Receive data+
4
Not connected

Advanced System Management ports

Your server has three communication ports dedicated to the Netfinity Advanced
System Management Processor. One port uses a standard D-shell serial-port
connector, connector C. The other two ports, which are used for the RS-485
function, use a dual RJ-45 connector.
You can attach a dedicated modem to the D-shell system-management connector
on the rear of your server to communicate with the integrated Netfinity Advanced
System Management Processor.
84
Hardware Maintenance Manual: xSeries 230 Models 6RY, 61Y
where d and path are the drive and path where the driver is located, and x and
y are the PCI slot numbers where the redundant pair is located.
The slot number associated with the integrated Ethernet controller can vary
depending on the configuration of the server. To determine the slot number,
load the driver with no parameters. The driver will display the available slot
numbers. The slot number that is greater that 10000 will be the slot number of
integrated Ethernet controller. When the slot number of the integrated Ethernet
controller is determined, reload the driver with the appropriate parameters.
of the failover function and the location of the redundant pair. You can use the
NetWare Monitor to view the custom counters.
handled by the secondary Ethernet controller, the traffic does not
automatically switch back to the primary adapter when the primary adapter
comes back online. In this case, issue the command:
LOAD d:\path\PCNTNW SCAN
where d and path are the drive and path where the driver is located. This
command causes the device driver to locate the primary adapter and switch
the Ethernet traffic to it.
Pin
Signal
5
Not connected
6
Receive data -
7
Not connected
8
Not connected

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xseries 230 61y

Table of Contents