Table 5. UNIX LLI driver messages for the Ethernet controller (continued)
pnt0-6
Cannot allocate memory for the adapter during an interrupt. Please check your Streams
parameters.
Explanation: On a SunSoft Solaris system, this message indicates that the system is out of
Streams memory blocks. Action: Use the CRASH utility to increase the number of Streams
memory blocks. Modify the interrupt request (IRQ) settings in the Configuration/Setup
Utility program, or run the NETCONFIG program to match the hardware settings.
pnt0-7
Cannot allocate memory for the adapter during reset. Please check your Streams parameters.
Explanation: The system is out of Streams memory blocks. Action: Use the CRASH utility to
increase the number of Streams memory blocks.
pnt0-11
Device not found!
Explanation: The driver cannot find an Ethernet controller. Action: Verify that the Ethernet
controller is enabled. If the Ethernet controller is enabled, run the diagnostic programs.
pnt0-12
Device failed checksum test!
Explanation: The driver cannot find an Ethernet controller. Action: Verify that the Ethernet
controller is enabled. If the Ethernet controller is enabled, run the diagnostic programs.
pnt0-13
add_intr_handler failed! Interrupts already enabled.
Explanation: The interrupt request (IRQ) that was specified, or the IRQ that was found,
conflicts with other devices in the server. Action: Modify your hardware settings.
Cannot locate hardware.
pnt0-14
Explanation: The SunSoft Solaris driver cannot find any Ethernet controller. Action: Verify
that the Ethernet controller is enabled. If the Ethernet controller is enabled, run the diagnostic
programs.
pnt0-15
No more devices to open.
Explanation: The SunSoft Solaris driver cannot find any more Ethernet controllers. Action:
Verify that additional IBM Netfinity 10/100 Fault Tolerant Adapters are present or replace the
Ethernet adapter that fails to respond. If the problem persists, run the diagnostic programs.
pnt0-17
Device fault...Reset initiated!
Explanation: The SunSoft Solaris driver has been reset due to a device fault. Action: Verify
that additional IBM Netfinity 10/100 Fault Tolerant Adapters are present or replace the
Ethernet adapter that fails to respond. If the problem persists, run the diagnostic programs.
pnt0-19
IRQ found for PCnet hardware does not match space.c (or pnt.conf)!
Explanation: This is a warning message referring to the interrupt request (IRQ) that the
SunSoft Solaris driver found in the system. Action: Ignore this message if you are sure that
this is what you want to do. Otherwise, run the NETCONFIG program to match the
hardware settings
pnt0-20
add_intr_handler failed! Unknown interrupt type.
Explanation: The interrupt request (IRQ) that was specified, or the IRQ that was found,
conflicts with other devices in the server. Action:
Modify your hardware settings.
v
Run the NETCONFIG program to search for another Ethernet controller.
v
25
Diagnostics