Stop Lever S/Z/T/U; Stop Lever C; A 11.00 Remote Engine Controls; A 11.10 Stop Devices - Hatz Diesel 1D30 S Workshop Manual

1 d series
Table of Contents

Advertisement

A 11.00 Remote engine controls

A 11.10 Stop devices

Version A 11.10.1

Stop lever S/Z/T/U

Preparations: –
Dismantling:
– Remove in numerical sequence 1...4.
– Remove timing cover (M 11.00).
– Remove lever 5.
Bushing 6 may remain
Inspection / repair:
– Check lever 5 and bushing 6 for wear or
any other damage.
Assembly:
– Press bushing 6 firmly in (if necessary).
Apply high strength locking agent as
specified !
– Bring bushing 6 to a position to have the
lever 5 just in the centre of the respective
contact face of the governor lever.
– Assemble in reverse sequence 5...1.
NOTE:
Hold stop lever 3 against tightening force of
Hex.-nut 1 to avoid excessive stress on
governor lever.
– Finish assembling.
2
1D . . / 03.06
Version A 11.10.2

Stop lever C.

Preparations: –
Dismantling:
– Remove in numerical sequence 1...10.
For further repair remove capsule parts
as required to have access to standard
engine respectively to bush 11 and lever 12.
Inspection / Repair:
– Check lever 5 and bushing 6 for wear or
any other damage.
Assembly:
– Assemble in reverse sequence.
NOTE:
Hold lever 9 against tightening force of
shaft 8 to avoid excessive stress on go-
vernor lever.
Hold lever 3 against tightening force of
Hex.-nut 1 to avoid excessive stress on
linkage and/or governor lever.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents