8) TECHNICAL SPECIFICATIONS (continued)
8-4) REMOTE PORT (DB 9 female connector)
Level
Data Rate
8-5) ROOM COMMAND (3.5 jack female connector)
NOTE : The ROOM (+12 Vdc Trigger) Command is activated by the AC Power Switch (ON/OFF).
Command level
Output Current
Connection
3.5 JACK MALE CONNECTOR (STEREO or MONO)
Command
Ground
8-6) ENVIRONMENTAL
Power Supply
Storage Temperature
Operating temperature
Maximum ambient operating temperature
Hygrometry
Dimensions
Weight
PAGE 18
: RS-232
: 9600 Bauds, 8 data bits, 1 stop bit, no parity bit
: • If AC Power Switch = ON : command = + 12 Vdc
• If AC Power Switch = OFF : command = 0 Vdc
: 0.1 A max at + 12 Vdc
: Internal CE / UL / CSA / IEC 950 (50 W), universal, automatic
: Input : 100 VAC to 250 VAC ; 50-60 Hz ; I = 1 A Max.
: -25°C to +85°C
: 0°C to 50°C
: < 40°C
: 10% to 80% (without condensation)
: D 300 x W 440 x H 44mm / D 11.8" x W 17.3" x H 1.74"
: 3.4 kg / 7.48 lbs.
ANALOG WAY
SMS100 - ED 07/01
Need help?
Do you have a question about the SMS100 Smart Scaler and is the answer not in the manual?