Video Level Adjustment (1); Bvp-E30/E30P M-V1 - Sony BVP-E30 Maintenance Manual

Color video camera
Hide thumbs Also See for BVP-E30:
Table of Contents

Advertisement

5-4-2. Video Level Adjustment (2)
Equipment : Oscilloscope
Preparations
. Turn the power off, and then disconnect the CCU
connected to the camera, and connect the AC-550/
550CE to the camera.
. Remove the left side panel. (Refer to Section 1-5.)
. OUTPUT/DCC switch (on the side panel) →
BARS/OFF
. Menu setting
MENU : SERVICE
PAGE :
DPR TRINNING
Adjustment Procedures
1. Y Level Adjustment
Test Point :
TP502 (GND : E501) /DPR-261
Adjustment Point
. ITEM :
Y LEVEL
Specifications : NTSC : A = 714 ± 2 mV
PAL :
(NTSC)
(Oscilloscope)
(PAL)
(Oscilloscope)

BVP-E30/E30P M-V1

A = 700 ± 2 mV
A
A
2. R-Y level Adjustment
Test Point :
TP503 (GND : E501) /DPR-261
Adjustment Point
. ITEM :
R-Y LEVEL
Specifications : NTSC : A = 700 ± 2 mV
PAL :
(NTSC)
A
(Oscilloscope)
(PAL)
A
(Oscilloscope)
A
E1
TP1
B
C
D
E
F
G
H
J
E2
K
L
M
11
10
9
8
7
DPR-261 board (A side)
A = 525 ± 2 mV
E501
TP501
TP502
TP503
TP800
5
4
3
2
1
6
5-11 (E)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bvp-e30pBvp-e30wsBvp-e30wsp

Table of Contents