Black-Box: Record Of Alarms, Battery Management Parameters, Partial Hour Counter - Clarke Focus II Micro Rider 26D Service Manual

Hide thumbs Also See for Focus II Micro Rider 26D:
Table of Contents

Advertisement

BLACK-BOX: RECORD OF ALARMS, BATTERY MANAGEMENT PARAMETERS, PARTIAL HOUR
COUNTER
The data indicated in the following table (ALARMS, BATTERY MANAGEMENT DATA) are stored in the non-volatile memory of the
electronic board and can be recalled and displayed by the external programmer (ITALSEA UNIVERSAL PROGRAMMER, NILFISK
P/N 9097297000) connect to port J9. For each stored datum (event) the value HOURS.MINUTES of the TOTAL hour counter is
associated when the alarm occurred. The last 20 events are stored. When the total number of events is used up, the next events
overwrite the older ones.
The data are shown on the programmer display, listed by decreasing order (starting from the latest) as: DATUM - HOUR (1 per
page). The UP and DOWN buttons are used to select 1 page at a time. All the stored paged can be scrolled. The "info" button
shows the DATUM - EVENT DESCRIPTION for the selected line.
DATUM
G2
EEPROM error
G3
General thermal protection
G4
Blown F2 fuse
G5
Wrong KEY sequence
G6
No signal from BATTERY CHARGER
G7
Battery undervoltage
G8
Serial communication error with dashboard electronic board
G9
Battery voltage drop
F2
Brush motor protection intervention
F3
VACUUM SYSTEM overcurrent
F4
DECK ACTUATOR position irregularity
F5
VACUUM SYSTEM power section damage
F6
PRESSURE SWITCH signal fault
F7
VACUUM SYSTEM output short circuit
F8
Function general relay fault
t2
Drive system amperometric protection intervention
t3
Electromagnetic brake not present
t5
Drive system power section damage
t6
Pedal input not admitted
t7
Drive system overcurrent
t8
Drive system relay fault
GB-N
Time of continuous use with discharged batteries
GC
Charging cycle interrupted before completion
GD-N
Charging phase duration
Service Manual -
EVENT DESCRIPTION
FOCUS II Micro Rider
ELECTRICAL SYSTEM
Condition
See alarm code description
See alarm code description
See alarm code description
See alarm code description
See alarm code description
See alarm code description
See alarm code description
See alarm code description
See alarm code description
See alarm code description
See alarm code description
See alarm code description
See alarm code description
See alarm code description
See alarm code description
See alarm code description
See alarm code description
See alarm code description
See alarm code description
See alarm code description
See alarm code description
N = Number of hours from the ignition with KEY to switching off
with B+ - B- < THRESHOLD2, if > 10 min.
Battery charger disconnection before PHASE IV (= with red or
yellow LED on)
N = Number of hours from battery charger connection to
completion of PHASE II (red LED on) if < 4
ENGLISH
63

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Focus ii micro rider 28 boost

Table of Contents