Display Of Current Values Of Significant Variables, Hour Counters And Stored Alarms - Clarke Focus II Micro Rider 26D Service Manual

Hide thumbs Also See for Focus II Micro Rider 26D:
Table of Contents

Advertisement

DISPLAY OF CURRENT VALUES OF SIGNIFICANT VARIABLES, HOUR COUNTERS AND STORED
ALARMS
1.
Turn the ignition switch to "0".
2.
Open the electrical component compartment.
3.
Connect the
ITALSEA programmer, NILFISK P/N 9097297000 to the function electronic board connector J9 (A).
4.
Turn the ignition switch to "I".
5.
Scroll with the UP and DOWN buttons the pages in the order shown in the table below.
Variable description
Software Release
Supply Voltage
Ref. Voltage
Drive Motor Voltage
Drive Motor Current
Brushes Current
Vacuum Current
Heatsink Temp.
Hour counter: total
Hour counter: drive system
Hour counter: brushes
Hour counter: vacuum
Logged Alarm-N
(*)
The value is the same as the voltage drop on the F1 fuse, which is proportional to the current but does not have the same
value in Amp.
(**)
See BLACK-BOX paragraph
Service Manual -
VA-
VA+
J6
J5
J4
Value meaning
Software version loaded on the electronic board
Battery voltage (V)
Drive pedal input voltage (V)
Drive system motor output voltage (V)
Drive system motor current (A)
Brush deck motor current (mV) (*)
Vacuum system motor current (A)
Temperature detected on the electronic board heatsink (°C)
TOTAL HOUR COUNTER (h.min)
DRIVE SYSTEM HOUR COUNTER (h.min)
BRUSH HOUR COUNTER (h.min)
VACUUM SYSTEM HOUR COUNTER (h.min)
ALARM STORAGE (possible) (**)
FOCUS II Micro Rider
ELECTRICAL SYSTEM
M2
M1
J8
J7A
J9
J7B
J1
J3
J2
ENGLISH
A
P100507