FUNCTION ELECTRONIC BOARD ERROR CODES

The function electronic board indicates a series of alarms codes in case of malfunction of one or more systems, and in case of
abnormal conditions detected in the input signals.
The alarms are shown on the display (71) (except "F6") by 2 signs following each other: "AL" and "XX", where XX is the alarm code
(see the descriptions in the following tables).
Also, the alarms are repeated (in case of display malfunction) by the diagnostic LEDs (yellow and red) on the electronic board, as
described in the following tables.
Alarm Code =
No. of flashes
G2
EEPROM error
G3
General thermal protection
G4
Blown F2 fuse
G5
Wrong KEY sequence
G6
No signal from BATTERY CHARGER
G7
Undervoltage
Serial communication error with dashboard
G8
electronic board
G9
Battery voltage drop
Alarm Code =
No. of flashes
F2
BRUSH motor amperometric protection
F3
VACUUM SYSTEM amperometric protection
F4
DECK ACTUATOR position irregularity
F5
VACUUM SYSTEM power section damage
F6
PRESSURE SWITCH signal fault
F7
VACUUM SYSTEM output short circuit
F8
Function general relay fault
All "general" and "function" alarms, and their relevant effects remain until reset from KEY input. In case of simultaneous errors, the
one with greater priority is shown first (priority order is opposite to the number of flashes).
Service Manual -
General Alarms (YELLOW LED + RED LED FLASHING)
Meaning
EEPROM error
Heatsink temperature > 90 °C
V > 1 V on F2
Wrong key sequence
No signal from battery charger
B+ - B- < THRESHOLD2 for t >10"
No signal or decoding error
DeltaV (neg.)> 3 V on battery voltage
Function Alarms (RED LED FLASHING)
Meaning
Voltage higher than the safety threshold
Vacuum system abnormal electrical input >
30 A for T>10 s
End-of-stroke microswitch configuration not
plausible or end-of-stroke not reached within
10"
CC MOSFET
Pressure switch Vout > 4.0 V
I > 2 * 50 A
Always closed / opened
FOCUS II Micro Rider
ELECTRICAL SYSTEM
Condition
Function block + Default setting
reset
Function block
Function block
Function block
The charging battery phase is not
shown
Function block
No block
Drive system + electromagnetic
brake block
Condition
Brush electromagnetic switch
output block
Vacuum system block
Deck actuator block
Vacuum system block
Water level visualisation missing
+ water flow and % detergent
management fault
Vacuum system block
Function block
ENGLISH
Effect
Effect