Common Error Codes - Clarke 00310S Operator's Manual

Rider scrubber rotary, cylindrical and boost (manual steering)
Hide thumbs Also See for 00310S:
Table of Contents

Advertisement

Available languages

Available languages

ENGLISH
EN
ERROR
CODE
1500
1501
1507
1600
3100
3101
3102
3103
3104
3105
7600
7603
7700
7800
7802
9000
2F01
Page -28-
Form No. 71171A
FOCUS Rider Scrubber

Common Error Codes

CAUSE
Check brake and wiring for
short circuit.
High battery voltage.
Probable short circuit of
output device.
Open circuit on brush motors
or brush motor wiring.
Possible short circuit on
brush motors or wiring.
Open circuit on vacuum motor
Open circuit on traction motor.
Traction motor current has
exceeded current limit for the
fold back time.
Brushes not fi tted.
Drive system activated prior
to turning key switch "ON".
ACTION
Make sure manual override is not engaged.
Poor or corroded connection to the
battery.
Check the traction, brush and vac motor
connections on the trio and check wiring
from these connectors down to the traction,
brush and vac motors.
Check the brush motor connection on the trio
and check the wiring from this
connector down to the brush motor.
Check connector to trio and vacuum motor
Check the traction motor connection on
trio and wiring down to motor.
Excessive driving up an incline, or machine
driven up against an obstacle or step.
Place brushes or pads onto machine.
Release traverse switch and reactivate.
Clarke
®
Operator's Manual (EN) - Focus Rider

Advertisement

Table of Contents
loading

This manual is also suitable for:

00310c00311s00311c00312s00312c00317s ... Show all

Table of Contents