6. Carefully pull the piezo connector from the piezo jack on the handle PCB.
7. Disconnect the flex cables from the handle PCB and remove the PCB.
To replace the handle PCB or handle assembly
1. Remove the handle assembly as described in the previous procedure.
2. Position the new handle PCB as shown in the next illustration. Part of the board has
2-6
You are now ready to replace the handle assembly. For help, see the next procedure.
To remove the handle PCB, continue with the next step.
You are now ready to replace the handle PCB. For help, continue with the next
procedure.
To replace the handle assembly, continue with step 11 using the new assembly.
To replace the handle PCB, continue with the next step.
been omitted for clarity.