Maintenance Procedures - WAGNER PEM-X1 Original Operating Manual

Manual powder spray gun
Table of Contents

Advertisement

VERSION 09/2012
OPERATING MANUAL
Incorrect maintenance!
Risk of injury and damage to the equipment.
8.2.3

MAINTENANCE PROCEDURES

The maintenance intervals should be adapted by the operator depending on the level of
use and if necessary the level of soiling.
In doubt, we recommend to contact J. Wagner AG's specialist personnel.
The valid health and safety specifi cations and safety instructions provided in chapter 4
must be adhered to for all maintenance work.
Maintenance work
Blow out gun and check for sintering
Check gun settings
Check gun discharge pressure
Blow out powder hoses
Check grounding
Check compressed air quality
Check gun voltage
Check powder hoses for bends and sintering
ORDER NUMBER DOC 2326020
WARNING
If contact with powder materials or cleaning agents causes skin
irritation, appropriate precautionary measures must be taken,
e.g. wearing protective clothing.
The footwear worn by operating staff must comply with
EN ISO 20344. The measured insulation resistance must not
exceed 100 MΩ (megaohms).
The protective clothing, including gloves, must comply with
EN ISO 1149-5. The measured insulation resistance must not
exceed 100 MΩ (megaohms).
Point in time
per shift
weekly
x
x
x
x
PEM-X1
x
x
x
x
36