TECHNICAL DATA

Dimensions:
Length/width/height
Weight
Electrical:
Input voltage
Input current
Frequency
Output voltage
max. Corona current
Polarity
Construction type
Protection class
Pneumatic:
Input air pressure (atomizer air volume)
Powder output quantity
Ambient conditions:
Operating temperature range
Relative humidity
Outgoing air containing oil!
Risk of poisoning if inhaled.
Insuffi cient paint application quality.
Ambient conditions:
If low-melting powders are used, the ambient temperature may have to be below 30 °C;
86 °F.
Volume measures:
for volumes specifi ed in Nm³ (standard cubic meters). One standard cubic meter is one
cubic meter of gas at 0 °C and 1.013 bar.
ORDER NUMBER DOC 2326020
see chapter 5.3.1
490 g; 1.08 lbs
maximum of 22 Vpp
maximum of 0.9 A
19 - 30 kHz
maximum of 100 kV DC
120 μA
negative
in accordance with EN 50050-2
IP 64
maximum of 3 bar; 0.3 MPa, 43.51 psi
maximum of 450 g/min; 0.99 lbs/min.
5 - 45 °C; 41 - 113 °F
< 75 %
WARNING
Make compressed air free from oil and water available (quality
standard 3.5.2 according to ISO 8573.1) 3.5.2 = 5 μm / +7 °C;
44.6 °F / 0.1 mg/m³.