3.3.2.3

VOLTAGE SLEW RATE

Use "
", "
1.
3-20 shows.
2.
Use the numeric keys (
Take example by 62150H-600S, the output voltage slew rate of the DC Power Supply is
set as Figure 3-21 shows. The maximum input Slew Rate is 20V/mS and the minimum is
0.001V/mS. The output of DC Power Supply will use the slew rate to rise to the set
output voltage while the fall slew rate is limited by load.
Press "
" to confirm.
ENTER
3.
Press "
" to return to the MAIN PAGE.
4.
EXIT
The minimum transient time is (ΔT) = 0.5 ms.
" keys to move the cursor to the column to be set as Figure
Figure 3-20
) or "Rotary" (
0
9
~
Vo
SR
Δ V
Δ T
Figure 3-21
) knob to set the value.
V
T
Time(mS)