Chroma 62000H Series Operating & Programming Manual page 214

Programmable dc power supply
Hide thumbs Also See for 62000H Series:
Table of Contents

Advertisement

Programmable DC Power Supply (with Solar Array Simulation) 62000H Series
Operating & Programming Manual
Query Syntax:
Return Parameter: <NR1>
Query Example:
Return Example: 1000
11.
SAS:SANDIA:TMPREF
Description:
Syntax:
Parameter:
Example:
Query Syntax:
Return Parameter: <NRf+>
Query Example:
Return Example: -1.000000e+02
12.
SAS:SANDIA:BETA
Description:
Syntax:
Parameter:
Example:
Query Syntax:
Return Parameter: <NRf+>
Query Example:
Return Example: -2.000000e+00
13.
SAS:SANDIA:FF
Description:
Syntax:
Parameter:
Example:
Query Syntax:
Return Parameter: <NRf+>
Query Example:
Return Example: -2.000000e+00
14.
SAS:SANDIA:IRR
Description:
Syntax:
Parameter:
Example:
Query Syntax:
Return Parameter: <NR1>
Query Example:
Return Example: 1000
15.
SAS:SANDIA:TMP
Description:
Syntax:
Parameter:
Example:
5-48
SAS:SANDIA:IRRREF?
SAS:SANDIA:IRRREF
It sets the temperature reference in SANDIA Mode.
SAS:SANDIA:TMPREF <NRf+>
<NRf+>
SAS:SANDIA:TMPREF 100
SAS:SANDIA:TMPREF -100
SAS:SANDIA:TMPREF?
SAS:SANDIA:TMPREF?
It sets the BETA parameter in SANDIA Mode.
SAS:SANDIA:BETA <NRf+>
<NRf+>
SAS:SANDIA:BETA 0
SAS:SANDIA:BETA -2
SAS:SANDIA:BETA?
SAS:SANDIA:BETA?
It sets the fill factor in SANDIA Mode.
SAS:SANDIA:FF <NRf+>
<NRf+>
SAS:SANDIA:FF 0.4
SAS:SANDIA:FF 0.95
SAS:SANDIA:FF?
SAS:SANDIA:FF?
It sets the irritation in SANDIA Mode.
SAS:SANDIA:IRR <NR1>
<NR1>
SAS:SANDIA:IRR 1000
SAS:SANDIA:IRR 3000
SAS:SANDIA:IRR?
SAS:SANDIA:IRR
It sets the temperature in SANDIA Mode.
SAS:SANDIA:TMP <NRf+>
<NRf+>
SAS:SANDIA:TMP 100

Advertisement