14. IVCurve:CONFigure:FILTer
Description:
Syntax:
Query Syntax:
Return Parameter: <NR1>
Example:
Query Example:
Return Example:
15. IVCurve:CONFigure:SPEed
Description:
Syntax:
Parameter:
Query Syntax:
Return Parameter: SLOW | MIDDLE | FAST
Example:
Query Example:
Return Example:
16. IVCurve:CONFigure:MARGIN
Description:
Syntax:
Query Syntax:
Return Parameter: <NR1>
Example:
Query Example:
Return Example:
It sets the IV-Curve measurement signal which is the cutoff
frequency (unit: Hz) of input filter.
IVCurve:CONFigure: FILTer <NR1>
IVCurve:CONFigure: FILTer?
IVC:CONF:FILT 1000
(It sets the input filter in IV-Curve mode to1000Hz.)
IVC:CONF:FILT?
NR1
It sets the IV-Curve output response speed.
IVCurve:CONFigure:SPEed
SLOW | MIDDLE | FAST
IVCurve:CONFigure:SPEed?
IVC:CONF:SPE FAST
(It sets the IV-Curve output response speed to FAST.)
IVC:CONF:SPE FAST?
SLOW | MIDDLE | FAST
It sets the IV-Curve margin (unit: %.)
IVCurve:CONFigure:MARGIN <NR1>
IVCurve:CONFigure:MARGIN?
IVC:CONF:MARGIN 100
(It sets the IV-Curve margin to 100%.)
IVC:CONF:MARGIN?
<NR1>