*IDN?
Identification Query
Type:
System interface
Description:
This query requests the 62000H to identify itself.
Query Syntax:
*IDN?
Query Example:
*IDN?
String
CHROMA ATE
62150H-600S
123456
01.00
Return Example:
CHROMA ATE, 62150H-600S,123456,01.00
*OPC
Operation Complete Command
Type:
Device status
Description:
This command causes the interface to set the OPC bit (bit 0) of the
Standard Event Status register when the DC Power Supply has
completed all pending operations.
Syntax:
*OPC
Parameter:
None
*OPC?
Operation Complete Query
Type:
Device status
This query always returns ASCII "1".
Description:
Query Syntax:
*OPC?
Return Parameter: <NR1>
Query Example:
1
*RCL
Recall Instrument State Command
Type:
Device status
Description:
This command restores the High Slew Rate Load to a state that was
previously stored in memory with the *SAV command to the specified
location (see *SAV).
Syntax:
*RCL <NR1>
Parameter:
None
Example:
*RCL 1
*RST
Reset Command
Type:
Device status
Description:
Reset System
Syntax:
*RST
Parameter:
None
*SAV
Save Command
Type:
Device status
Description:
This command stores the present state of the DC Power Supply and the
states of current mode in a specified location in memory.
Syntax:
*SAV
Example:
*SAV
*SRE
Service Request Enable Command/Query
Type:
Device status
Description:
This command sets the condition of the Service Request Enable
register, which determines which events of the Status Byte register (see
*STB) are allowed to set the MSS (Master Status Summary) bit. A "1" in
Description
Manufacturer
Model name
Serial No.
Firmware version
Remote Operation
5-23