• Rank Level: Select Debug admin
Then click Apply.
Open another browser and log into the X6004 using the newly created debug
2
admin account.
Go to Maintenance > Administration > Diagnostics > Packet Capture and
3
fill in the following information.
• Interface: LAN
• Host: 192.168.1.150
• Protocol: All
• Stop capture after: 3000 packets
• Stop capture after: 600 seconds
Then click Capture Now.
Re-initialize the SIP phone. This helps to get a complete packet capturing.