4   INSTALLATION
4.2

Lifting instructions

These units are equipped with a handle for carrying purposes.
WARNING!
Electric shock can kill. Do not touch live electrical parts. Disconnect input power conductors
from de-energized supply line before moving the welding power source.
WARNING!
Falling equipment can cause serious personal injury and equipment damage.
Lift the unit with handle on top of case.
4.3

Mains supply

NOTE!
Mains supply requirements
This equipment complies with IEC 61000-3-12 provided that the short-circuit power is greater
than or equal to S
It is the responsibility of the installer or user of the equipment to ensure, by consultation with
the distribution network operator if necessary, that the equipment is connected only to a supply
with a short-circuit power greater than or equal to S
1. Rating plate with supply connection data.
0463 862 001
at the interface point between the user's supply and the public system.
scmin
.
scmin
- 13 -