1.6

CONNECTING TO WATER SUPPLY LINES

NOTE: In addition to the following, adhere to WATER SUPPLY WARNINGS AND CAUTIONS,
Page 7.
For the plain water supply line, the inlet water flowing pressure should be at least 75 PSI (0.517 MPA). If the water
pressure is lower than 75 PSI (0.517 MPA) flowing, use a water booster system.
If the water flowing pressure is lower than 75 PSI (0.517 MPA) at the plain water inlet and a water booster is NOT
installed, water products will not hold a proper flow rate or water/syrup ratio. Flow conditions at the nozzle can also
be affected, causing poor nozzle coning and mixing.
For the soda water supply line, do not exceed 50 PSI (0.345 MPA) for the inlet water static pressure going into the
carbonator pump. If the static water pressure exceeds 50 PSI (0.345 MPA), install a water regulator before the
carbonator water inlet.
The Lancer Water Booster/Tank (PN MC-163172) is offered as a kit. The water booster must be installed as close
as possible to the plain water circuit inlet.
Install the water regulator (Lancer PN 18-0306) included with unit as close as possible to the water carbonator
pump inlet. The recommended water pressure value feeding the carbonator is a minimum of 25 PSI (0.172 MPA). If
the normal water pressure does not exceed 50 PSI (0.345 MPA), but fluctuates over this value (for example, when
water usage on other equipment connected to the same water supply causes pressure spikes), use a water regula-
tor.
A. Installer should provide new beverage tubing that meets the IEC Standard 61770. Do not reuse
beverage tubing. Lancer beverage tubing kits are available for purchase. Contact your Sales
Representative or Lancer Customer Service for more information. Use a filter in the water line.
Failure to do so can result in equipment damage and beverage off-taste. Check the water filter
periodically, as required by local conditions.
! CAUTION
FAILURE TO DISCONNECT THE MOTOR POWER SUPPLY WILL DAMAGE THE CARBONATOR MOTOR, THE
PUMP AND VOID THE WARRANTY.
! PRECAUCIÓN
SI NO DESCONECTA LA ALIMENTACIÓN ELÉCTRICA DEL MOTOR PODRÍAN DAÑARSE LA BOMBA Y EL
MOTOR DEL CARBONATADO Y ANULAR LA GARANTÍA.
! ATTENTION
LE FAIT DE NE PAS MAINTENIR LE DÉGAGEMENT SPÉCIFIÉ FERA SURCHAUFFER LE COMPRESSEUR ET
AURA COMME CONSÉQUENCE UNE DÉFAILLANCE DU COMPRESSEUR.
B. Protect the water supply by means of an air gap, a backflow prevention device, or another
approved method that complies with NSF standards. A leaking inlet water check valve will
allow carbonated water to flow back through the pump when it is shut off and contaminate
the water supply. Ensure the backflow prevention device complies with ASSE and local
standards. It is the responsibility of the installer to ensure compliance.
C. Provide an adequate potable water supply. Water pipe connections and fixtures directly
connected to a potable water supply must be sized, installed, and maintained according to
federal, state, and local laws.
! CAUTION
DO NOT CONNECT TO A HOT WATER OR SOFT WATER SOURCE. THIS CAUSES EXCESSIVE FOAMING.
! PRECAUCIÓN
NO LO CONECTE A UNA FUENTE DE AGUA CALIENTE O AGUA BLANDA. ESTO PROVOCA UN EXCESO DE
ESPUMA.
! ATTENTION
NE PAS RACCORDER À UN CHAUFFE-EAU OU D'UNE SOURCE D'EAU DOUCE. CELA PROVOQUE UN MOUS-
SAGE EXCESSIF.AURA COMME CONSÉQUENCE UNE DÉFAILLANCE DU COMPRESSEUR.